From afdf651c628281a890b161fbdb446b59a53d7c65 Mon Sep 17 00:00:00 2001
From: Lucie Dubrunfaut <123162035+lucie-dubrunfaut@users.noreply.github.com>
Date: Tue, 17 Dec 2024 14:30:36 +0100
Subject: [PATCH] CTOR-1150 : Refresh network-viptela-snmp (#3847)
CTOR-1150
---
.../procedures/network-viptela-snmp.md | 757 ++++++++++++++----
.../procedures/network-viptela-snmp.md | 752 +++++++++++++----
2 files changed, 1239 insertions(+), 270 deletions(-)
diff --git a/i18n/fr/docusaurus-plugin-content-docs-pp/current/integrations/plugin-packs/procedures/network-viptela-snmp.md b/i18n/fr/docusaurus-plugin-content-docs-pp/current/integrations/plugin-packs/procedures/network-viptela-snmp.md
index 95aea30208a0..1cd7dcc96f6e 100644
--- a/i18n/fr/docusaurus-plugin-content-docs-pp/current/integrations/plugin-packs/procedures/network-viptela-snmp.md
+++ b/i18n/fr/docusaurus-plugin-content-docs-pp/current/integrations/plugin-packs/procedures/network-viptela-snmp.md
@@ -5,132 +5,157 @@ title: Viptela SNMP
import Tabs from '@theme/Tabs';
import TabItem from '@theme/TabItem';
-## Contenu du Pack
+## Dépendances du connecteur de supervision
+
+Les connecteurs de supervision suivants sont automatiquement installés lors de l'installation du connecteur **Viptela SNMP**
+depuis la page **Configuration > Gestionnaire de connecteurs de supervision** :
+* [Base Pack](./base-generic.md)
+
+## Contenu du pack
### Modèles
-Le Pack Centreon Viptela SNMP apporte 1 modèle d'hôte :
-* Net-Viptela-SNMP-custom
+Le connecteur de supervision **Viptela SNMP** apporte un modèle d'hôte :
+
+* **Net-Viptela-SNMP-custom**
+
+Le connecteur apporte les modèles de service suivants
+(classés selon le modèle d'hôte auquel ils sont rattachés) :
+
+
+
+
+| Alias | Modèle de service | Description |
+|:---------|:---------------------------------|:----------------------------------------------------------|
+| Cpu | Net-Viptela-Cpu-SNMP-custom | Contrôle du taux d'utilisation du CPU de la machine |
+| Disk | Net-Viptela-Disk-SNMP-custom | Contrôle du taux d'utilisation du disque de la machine |
+| Hardware | Net-Viptela-Hardware-SNMP-custom | Contrôle l'état du matériel |
+| Memory | Net-Viptela-Memory-SNMP-custom | Contrôle du taux d'utilisation de la mémoire vive |
+| Uptime | Net-Viptela-Uptime-SNMP-custom | Durée depuis laquelle le serveur tourne sans interruption |
+
+> Les services listés ci-dessus sont créés automatiquement lorsque le modèle d'hôte **Net-Viptela-SNMP-custom** est utilisé.
+
+
+
-Il apporte les Modèles de Service suivants :
+| Alias | Modèle de service | Description | Découverte |
+|:--------------------|:--------------------------------------------|:------------------------------------|:----------:|
+| Control-Connections | Net-Viptela-Control-Connections-SNMP-custom | Contrôle les connexions de contrôle | |
+| Gre-Tunnels | Net-Viptela-Gre-Tunnels-SNMP-custom | Contrôle les tunnels GRE | X |
+| Interfaces | Net-Viptela-Interfaces-SNMP-custom | Contrôle les interfaces | X |
-| Service Alias | Service Template | Default | Discovery |
-|:--------------------|:-------------------------------------|:--------|:----------|
-| Control-Connections | Net-Viptela-Control-Connections-SNMP | | |
-| Cpu | Net-Viptela-Cpu-SNMP | X | |
-| Disk | Net-Viptela-Disk-SNMP | X | |
-| Gre-Tunnels | Net-Viptela-Gre-Tunnels-SNMP | | X |
-| Hardware | Net-Viptela-Hardware-SNMP | X | |
-| Interfaces | Net-Viptela-Interfaces-SNMP | | X |
-| Memory | Net-Viptela-Memory-SNMP | X | |
-| Uptime | Net-Viptela-Uptime-SNMP | X | |
+> Les services listés ci-dessus ne sont pas créés automatiquement lorsqu'un modèle d'hôte est appliqué. Pour les utiliser, [créez un service manuellement](/docs/monitoring/basic-objects/services) et appliquez le modèle de service souhaité.
+
+> Si la case **Découverte** est cochée, cela signifie qu'une règle de découverte de service existe pour ce service.
+
+
+
### Règles de découverte
-| Rule name | Description |
-|:------------------ --------------|:------------------------------------------------------------------------|
-| Net-Viptela-SNMP-Interface-Name | Découvre les interfaces réseaux et supervise le statut et l'utilisation |
-| Net-Viptela-SNMP-Gre-Tunnel-Name | Découvre les tunnels GRE et supervise le statut et l'utilisation |
+#### Découverte d'hôtes
+
+| Nom de la règle | Description |
+|:----------------|:-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| SNMP Agents | Découvre les ressources via un scan réseau SNMP. Installez le connecteur [Generic SNMP](./applications-protocol-snmp.md) pour obtenir la règle de découverte et créez un modificateur pour le modèle d'hôte **Net-Viptela-SNMP-custom**. |
+
+Rendez-vous sur la [documentation dédiée](/docs/monitoring/discovery/hosts-discovery) pour en savoir plus sur la découverte automatique d'hôtes.
+
+#### Découverte de services
+
+| Nom de la règle | Description |
+|:---------------------------------|:--------------------------------------------------------------------------------------------------|
+| Net-Viptela-SNMP-Gre-Tunnel-Name | Découvre les tunnels GRE et en supervise le statut et l'utilisation |
+| Net-Viptela-SNMP-Interface-Name | Découvre les interfaces réseau en utilisant leur nom et supervise leur statut et leur utilisation |
+
+Rendez-vous sur la [documentation dédiée](/docs/monitoring/discovery/services-discovery)
+pour en savoir plus sur la découverte automatique de services et sa [planification](/docs/monitoring/discovery/services-discovery/#règles-de-découverte).
### Métriques & statuts collectés
+Voici le tableau des services pour ce connecteur, détaillant les métriques et statuts rattachés à chaque service.
+
-| Metric name | Description | Unit |
-| :-------------------------------------- | :------------------------------------------------------ | :---- |
-| control.connections.detected.count | Number of control connections detected | |
-| control.connections.down.count | Number of control connections with status down | |
-| control.connections.connect.count | Number of control connections with status connect | |
-| control.connections.handshake.count | Number of control connections with status handshake | |
-| control.connections.trying.count | Number of control connections with status trying | |
-| control.connections.challenge.count | Number of control connections with status challenge | |
-| control.connections.challengeResp.count | Number of control connections with status challengeResp | |
-| control.connections.challengeAck.count | Number of control connections with status challengeAck | |
-| control.connections.up.count | Number of control connections with status up | |
-| control.connections.tearDown.count | Number of control connections with status tearDown | |
-| status | Status for the control connection | |
+| Nom | Unité |
+|:-----------------------------------|:------|
+| control.connections.detected.count | count |
+| status | N/A |
-
-| Metric name | Description | Unit |
-| :------------------------- | :-------------- | :---- |
-| cpu.utilization.percentage | CPU utilization | % |
+| Nom | Unité |
+|:---------------------------|:------|
+| cpu.utilization.percentage | % |
-
-| Metric name | Description | Unit |
-| :-------------------- | :----------------------- | :---- |
-| disk.usage.bytes | Disk usage | B |
-| disk.free.bytes | Free disk | B |
-| disk.usage.percentage | Disk usage in percentage | % |
+| Nom | Unité |
+|:----------------------|:------|
+| disk.usage.bytes | B |
+| disk.free.bytes | B |
+| disk.usage.percentage | % |
-
-| Metric name | Description | Unit |
-| :----------------------------------------------- | :------------------------------------------------ | :---- |
-| gre_tunnels.detected.count | Number of GRE tunnels detected | |
-| gre_tunnels.operational.up.count | Number of GRE tunnels with status up | |
-| gre_tunnels.operational.down.count | Number of GRE tunnels with status down | |
-| gre_tunnels.operational.invalid.count | Number of GRE tunnels with status invalid | |
-| status | Status for the GRE tunnel | |
-| *source_ip~dest_ip*#gre_tunnel.packets.in.count | Number of incoming packets for the GRE tunnel | |
-| *source_ip~dest_ip*#gre_tunnel.packets.out.count | Number of outgoing packets for for the GRE tunnel | |
+| Nom | Unité |
+|:---------------------------------------|:------|
+| gre_tunnels.detected.count | count |
+| gre_tunnels.operational.up.count | count |
+| gre_tunnels.operational.down.count | count |
+| gre_tunnels.operational.invalid.count | count |
+| status | N/A |
+| *tunnels*~gre_tunnel.packets.in.count | count |
+| *tunnels*~gre_tunnel.packets.out.count | count |
-
-| Metric name | Description | Unit |
-|:----------------------------------------- |:--------------------------------------------- | :--- |
-| fan status | Status of the fan | |
-| led status | Status of the LED | |
-| nim status | Status of the NIM | |
-| pem status | Status of the PEM | |
-| pim status | Status of the PIM | |
-| usb status | Status of the USB | |
-| temperature status | Status of temperature probes | |
-| *probe_name*#hardware.temperature.celsius | Current temperature | C |
+| Nom | Unité |
+|:------------------------------------------|:------|
+| fan status | N/A |
+| led status | N/A |
+| nim status | N/A |
+| pem status | N/A |
+| pim status | N/A |
+| usb status | N/A |
+| temperature status | N/A |
+| *probe_name*#hardware.temperature.celsius | C |
-
-| Metric name | Description | Unit |
-|:--------------------------------------------------------- |:------------------------------------------------------- |:---- |
-| status | Status of the interface | |
-| *interface_name*#interface.traffic.in.bitspersecond | Incoming traffic going through the interface | b/s |
-| *interface_name*#interface.traffic.out.bitspersecond | Outgoing traffic going through the interface | b/s |
-| *interface_name*#interface.packets.in.error.percentage | Incoming errored packets going through the interface | % |
-| *interface_name*#interface.packets.in.discard.percentage | Incoming discarded packets going through the interface | % |
-| *interface_name*#interface.packets.out.error.percentage | Outgoing errored packets going through the interface | % |
-| *interface_name*#interface.packets.out.discard.percentage | Outgoing discarded packets going through the interface | % |
+| Nom | Unité |
+|:----------------------------------------------------------|:------|
+| status | N/A |
+| *interface_name*#interface.traffic.in.bitspersecond | b/s |
+| *interface_name*#interface.traffic.out.bitspersecond | b/s |
+| *interface_name*#interface.packets.in.error.percentage | % |
+| *interface_name*#interface.packets.in.discard.percentage | % |
+| *interface_name*#interface.packets.out.error.percentage | % |
+| *interface_name*#interface.packets.out.discard.percentage | % |
-
-| Metric name | Description | Unit |
-| :---------------------- | :------------------------- | :---- |
-| memory.usage.bytes | Memory usage | B |
-| memory.free.bytes | Free memory | B |
-| memory.usage.percentage | Memory usage in percentage | % |
-| memory.buffer.bytes | Buffers memory | B |
-| memory.cached.bytes | Cached memory | B |
+| Nom | Unité |
+|:------------------------|:------|
+| memory.usage.bytes | B |
+| memory.free.bytes | B |
+| memory.usage.percentage | % |
+| memory.buffer.bytes | B |
+| memory.cached.bytes | B |
-
-| Metric name | Description | Unit |
-| :-------------------- | :----------------- | :---- |
-| system.uptime.seconds | System uptime | s |
+| Metric name | Description | Unité |
+|:----------------------|:--------------|:------|
+| system.uptime.seconds | System uptime | s |
@@ -139,106 +164,566 @@ Il apporte les Modèles de Service suivants :
### Configuration SNMP
-Afin de superviser votre équipement, le SNMP v2 ou v3 doit être configuré.
+L'agent SNMP doit être activé et configuré sur l'équipement.
+Veuillez vous référer à la documentation officielle du constructeur/éditeur.
+Il se peut que votre équipement nécessite qu'une liste d'adresses autorisées à l'interroger soit paramétrée.
+Veillez à ce que les adresses des collecteurs Centreon y figurent bien.
### Flux réseau
-La communication doit être possible sur le port UDP 161 depuis le collecteur
-Centreon vers l'équipement supervisé.
+La communication doit être possible sur le port UDP 161 depuis le collecteur Centreon vers la ressource supervisée.
+
+## Installer le connecteur de supervision
-## Installation
+### Pack
+
+1. Si la plateforme est configurée avec une licence *online*, l'installation d'un paquet
+n'est pas requise pour voir apparaître le connecteur dans le menu **Configuration > Gestionnaire de connecteurs de supervision**.
+Au contraire, si la plateforme utilise une licence *offline*, installez le paquet
+sur le **serveur central** via la commande correspondant au gestionnaire de paquets
+associé à sa distribution :
-
+
-1. Installer le Plugin Centreon sur tous les collecteurs Centreon devant superviser des resources **Viptela SNMP** :
+```bash
+dnf install centreon-pack-network-viptela-snmp
+```
+
+
+
```bash
-yum install centreon-plugin-Network-Viptela-Snmp
+dnf install centreon-pack-network-viptela-snmp
+```
+
+
+
+
+```bash
+apt install centreon-pack-network-viptela-snmp
```
-2. Sur l'interface Web de Centreon, installer le Pack **Viptela SNMP** depuis la page **Configuration > Packs de plugins**.
+
+
+
+```bash
+yum install centreon-pack-network-viptela-snmp
+```
+
+
+2. Quel que soit le type de la licence (*online* ou *offline*), installez le connecteur **Viptela SNMP**
+depuis l'interface web et le menu **Configuration > Gestionnaire de connecteurs de supervision**.
+
+### Plugin
-
+À partir de Centreon 22.04, il est possible de demander le déploiement automatique
+du plugin lors de l'utilisation d'un connecteur. Si cette fonctionnalité est activée, et
+que vous ne souhaitez pas découvrir des éléments pour la première fois, alors cette
+étape n'est pas requise.
-1. Installer le Plugin Centreon sur tous les collecteurs Centreon devant superviser des resources **Viptela SNMP** :
+> Plus d'informations dans la section [Installer le plugin](/docs/monitoring/pluginpacks/#installer-le-plugin).
+
+Utilisez les commandes ci-dessous en fonction du gestionnaire de paquets de votre système d'exploitation :
+
+
+
```bash
-yum install centreon-plugin-Network-Viptela-Snmp
+dnf install centreon-plugin-Network-Viptela-Snmp
```
-2. Sur le serveur Central Centreon, installer le RPM du Pack **Viptela SNMP** :
+
+
```bash
-yum install centreon-pack-network-viptela-snmp
+dnf install centreon-plugin-Network-Viptela-Snmp
```
-3. Sur l'interface Web de Centreon, installer le Pack **Viptela SNMP** depuis la page **Configuration > Packs de plugins**.
+
+
+
+```bash
+apt install centreon-plugin-network-viptela-snmp
+```
+
+
+
+
+```bash
+yum install centreon-plugin-Network-Viptela-Snmp
+```
-## Configuration
+## Utiliser le connecteur de supervision
-### Hôte
+### Utiliser un modèle d'hôte issu du connecteur
-* Ajoutez un Hôte à Centreon depuis la page **Configuration > Hôtes**
-* Complétez les champs **Nom**, **Alias** & **IP Address / DNS** correspondant à votre serveur **Viptela SNMP**.
-* Appliquez le Modèle d'Hôte **Net-Viptela-SNMP-custom**
+1. Ajoutez un hôte à Centreon depuis la page **Configuration > Hôtes**.
+2. Complétez les champs **Nom**, **Alias** & **IP Address/DNS** correspondant à votre ressource.
+3. Appliquez le modèle d'hôte **Net-Viptela-SNMP-custom**.
-> Si vous utilisez SNMP en version 3, vous devez configurer les paramètres spécifiques associés via la macro SNMPEXTRAOPTIONS.
+> Si vous utilisez SNMP en version 3, vous devez configurer les paramètres spécifiques associés via la macro **SNMPEXTRAOPTIONS**.
> Plus d'informations dans la section [Troubleshooting SNMP](../getting-started/how-to-guides/troubleshooting-plugins.md#snmpv3-options-mapping).
-| Mandatory | Name | Description |
-|:----------|:-----------------|:---------------------------------------------------------|
-| | SNMPEXTRAOPTIONS | (Default: 'Configure your own SNMPv3 credentials combo') |
+| Macro | Description | Valeur par défaut | Obligatoire |
+|:-----------------|:---------------------------------------------------------------------------------------------------------------------------------------------------|:------------------|:-----------:|
+| SNMPEXTRAOPTIONS | Any extra option you may want to add to every command (a --verbose flag for example). Toutes les options sont listées [ici](#options-disponibles). | | |
+
+4. [Déployez la configuration](/docs/monitoring/monitoring-servers/deploying-a-configuration). L'hôte apparaît dans la liste des hôtes supervisés, et dans la page **Statut des ressources**. La commande envoyée par le connecteur est indiquée dans le panneau de détails de l'hôte : celle-ci montre les valeurs des macros.
+
+### Utiliser un modèle de service issu du connecteur
+
+1. Si vous avez utilisé un modèle d'hôte et coché la case **Créer aussi les services liés aux modèles**, les services associés au modèle ont été créés automatiquement, avec les modèles de services correspondants. Sinon, [créez les services désirés manuellement](/docs/monitoring/basic-objects/services) et appliquez-leur un modèle de service.
+2. Renseignez les macros désirées (par exemple, ajustez les seuils d'alerte). Les macros indiquées ci-dessous comme requises (**Obligatoire**) doivent être renseignées.
+
+
+
+
+| Macro | Description | Valeur par défaut | Obligatoire |
+|:---------------------------------|:-------------------------------------------------------------------------------------------------------------------------------------------------|:---------------------------|:-----------:|
+| FILTERPUBLICIP | Filter connections by public ip address | | |
+| FILTERPRIVATEIP | Filter connections by private ip address | | |
+| FILTERTYPE | Filter connections by type | | |
+| WARNINGCONNECTIONSCHALLENGE | Threshold | | |
+| CRITICALCONNECTIONSCHALLENGE | Threshold | | |
+| WARNINGCONNECTIONSCHALLENGEACK | Threshold | | |
+| CRITICALCONNECTIONSCHALLENGEACK | Threshold | | |
+| WARNINGCONNECTIONSCHALLENGERESP | Threshold | | |
+| CRITICALCONNECTIONSCHALLENGERESP | Threshold | | |
+| WARNINGCONNECTIONSCONNECT | Threshold | | |
+| CRITICALCONNECTIONSCONNECT | Threshold | | |
+| WARNINGCONNECTIONSDOWN | Threshold | | |
+| CRITICALCONNECTIONSDOWN | Threshold | | |
+| WARNINGCONNECTIONSHANDSHAKE | Threshold | | |
+| CRITICALCONNECTIONSHANDSHAKE | Threshold | | |
+| WARNINGCONNECTIONSTEARDOWN | Threshold | | |
+| CRITICALCONNECTIONSTEARDOWN | Threshold | | |
+| WARNINGCONNECTIONSTRYING | Threshold | | |
+| CRITICALCONNECTIONSTRYING | Threshold | | |
+| WARNINGCONNECTIONSUP | Threshold | | |
+| CRITICALCONNECTIONSUP | Threshold | | |
+| WARNINGCONNNECTIONSDETECTED | Threshold | | |
+| CRITICALCONNNECTIONSDETECTED | Threshold | | |
+| CRITICALSTATUS | Define the conditions to match for the status to be CRITICAL. You can use the following variables: %{status}, %{type}, %{privateIp}, %{publicIp} | %{status} !~ /up\|connect/ | |
+| WARNINGSTATUS | Define the conditions to match for the status to be WARNING. You can use the following variables: %{status}, %{type}, %{privateIp}, %{publicIp} | | |
+| EXTRAOPTIONS | Any extra option you may want to add to the command (a --verbose flag for example). Toutes les options sont listées [ici](#options-disponibles). | --verbose | |
+
+
+
+
+| Macro | Description | Valeur par défaut | Obligatoire |
+|:-----------------------|:-------------------------------------------------------------------------------------------------------------------------------------------------|:------------------|:-----------:|
+| WARNINGCPUUTILIZATION | Threshold | | |
+| CRITICALCPUUTILIZATION | Threshold | | |
+| EXTRAOPTIONS | Any extra option you may want to add to the command (a --verbose flag for example). Toutes les options sont listées [ici](#options-disponibles). | | |
-## Comment puis-je tester le Plugin et que signifient les options des commandes ?
+
+
+
+| Macro | Description | Valeur par défaut | Obligatoire |
+|:------------------|:-------------------------------------------------------------------------------------------------------------------------------------------------|:------------------|:-----------:|
+| WARNINGUSAGE | Threshold | | |
+| CRITICALUSAGE | Threshold | | |
+| WARNINGUSAGEFREE | Threshold | | |
+| CRITICALUSAGEFREE | Threshold | | |
+| WARNINGUSAGEPRCT | Threshold | | |
+| CRITICALUSAGEPRCT | Threshold | | |
+| EXTRAOPTIONS | Any extra option you may want to add to the command (a --verbose flag for example). Toutes les options sont listées [ici](#options-disponibles). | | |
+
+
+
+
+| Macro | Description | Valeur par défaut | Obligatoire |
+|:----------------------------|:-------------------------------------------------------------------------------------------------------------------------------------------------------|:-----------------------------------------------|:-----------:|
+| FILTERDESTIP | Filter tunnels by destination ip address | | |
+| FILTERSRCIP | Filter tunnels by source ip address | | |
+| WARNINGGRETUNNELPACKETSIN | Threshold | | |
+| CRITICALGRETUNNELPACKETSIN | Threshold | | |
+| WARNINGGRETUNNELPACKETSOUT | Threshold | | |
+| CRITICALGRETUNNELPACKETSOUT | Threshold | | |
+| WARNINGGRETUNNELSDETECTED | Threshold | | |
+| CRITICALGRETUNNELSDETECTED | Threshold | | |
+| WARNINGGRETUNNELSDOWN | Threshold | | |
+| CRITICALGRETUNNELSDOWN | Threshold | | |
+| WARNINGGRETUNNELSINVALID | Threshold | | |
+| CRITICALGRETUNNELSINVALID | Threshold | | |
+| WARNINGGRETUNNELSUP | Threshold | | |
+| CRITICALGRETUNNELSUP | Threshold | | |
+| CRITICALSTATUS | Define the conditions to match for the status to be CRITICAL. You can use the following variables: %{adminState}, %{operState}, %{sourceIp}, %{destIp} | %{adminState} eq "up" and %{operState} ne "up" | |
+| WARNINGSTATUS | Define the conditions to match for the status to be WARNING. You can use the following variables: %{adminState}, %{operState}, %{sourceIp}, %{destIp} | | |
+| EXTRAOPTIONS | Any extra option you may want to add to the command (a --verbose flag for example). Toutes les options sont listées [ici](#options-disponibles). | --verbose | |
+
+
+
-Une fois le Plugin installé, vous pouvez tester celui-ci directement en ligne
-de commande depuis votre collecteur Centreon en vous connectant avec
-l'utilisateur **centreon-engine**:
+| Macro | Description | Valeur par défaut | Obligatoire |
+|:-------------|:-------------------------------------------------------------------------------------------------------------------------------------------------|:------------------|:-----------:|
+| COMPONENT | Which component to check (default: '.*'). Can be: 'fan', 'led', 'nim', 'pem', 'pim', 'temperature', 'usb' | | |
+| EXTRAOPTIONS | Any extra option you may want to add to the command (a --verbose flag for example). Toutes les options sont listées [ici](#options-disponibles). | --verbose | |
+
+
+
+
+| Macro | Description | Valeur par défaut | Obligatoire |
+|:-------------------|:----------------------------------------------------------------------------------------------------------------------------------------------------------|:------------------------------------------------------|:-----------:|
+| OIDFILTER | Define the OID to be used to filter interfaces (values: ifDesc, ifAlias, ifName, IpAddr) | ifname | |
+| OIDDISPLAY | Define the OID that will be used to name the interfaces (values: ifDesc, ifAlias, ifName, IpAddr) | ifname | |
+| INTERFACENAME | Set the interface (number expected) example: 1,2,... (empty means 'check all interfaces') | | |
+| WARNINGINDISCARD | Threshold | | |
+| CRITICALINDISCARD | Threshold | | |
+| WARNINGINERROR | Threshold | | |
+| CRITICALINERROR | Threshold | | |
+| WARNINGINTRAFFIC | Threshold | | |
+| CRITICALINTRAFFIC | Threshold | | |
+| WARNINGOUTDISCARD | Threshold | | |
+| CRITICALOUTDISCARD | Threshold | | |
+| WARNINGOUTERROR | Threshold | | |
+| CRITICALOUTERROR | Threshold | | |
+| WARNINGOUTTRAFFIC | Threshold | | |
+| CRITICALOUTTRAFFIC | Threshold | | |
+| CRITICALSTATUS | Define the conditions to match for the status to be CRITICAL. You can use the following variables: %{admstatus}, %{opstatus}, %{duplexstatus}, %{display} | %{admstatus} eq "up" and %{opstatus} !~ /up\|dormant/ | |
+| WARNINGSTATUS | Define the conditions to match for the status to be WARNING. You can use the following variables: %{admstatus}, %{opstatus}, %{duplexstatus}, %{display} | | |
+| EXTRAOPTIONS | Any extra option you may want to add to the command (a --verbose flag for example). Toutes les options sont listées [ici](#options-disponibles). | --verbose | |
+
+
+
+
+| Macro | Description | Valeur par défaut | Obligatoire |
+|:------------------|:-------------------------------------------------------------------------------------------------------------------------------------------------|:------------------|:-----------:|
+| WARNINGBUFFER | Threshold | | |
+| CRITICALBUFFER | Threshold | | |
+| WARNINGCACHED | Threshold | | |
+| CRITICALCACHED | Threshold | | |
+| WARNINGUSAGE | Warning threshold on used memory (in B) | | |
+| CRITICALUSAGE | Critical threshold on used memory (in B) | | |
+| WARNINGUSAGEFREE | Warning threshold on free memory (in B) | | |
+| CRITICALUSAGEFREE | Critical threshold on free memory (in B) | | |
+| WARNINGUSAGEPRCT | Warning threshold on used memory (in %) | | |
+| CRITICALUSAGEPRCT | Critical threshold on percentage used memory (in %) | | |
+| EXTRAOPTIONS | Any extra option you may want to add to the command (a --verbose flag for example). Toutes les options sont listées [ici](#options-disponibles). | | |
+
+
+
+
+| Macro | Description | Valeur par défaut | Obligatoire |
+|:---------------|:-------------------------------------------------------------------------------------------------------------------------------------------------|:------------------|:-----------:|
+| WARNINGUPTIME | Warning threshold | | |
+| CRITICALUPTIME | Critical threshold | | |
+| EXTRAOPTIONS | Any extra option you may want to add to the command (a --verbose flag for example). Toutes les options sont listées [ici](#options-disponibles). | | |
+
+
+
+
+3. [Déployez la configuration](/docs/monitoring/monitoring-servers/deploying-a-configuration). Le service apparaît dans la liste des services supervisés, et dans la page **Statut des ressources**. La commande envoyée par le connecteur est indiquée dans le panneau de détails du service : celle-ci montre les valeurs des macros.
+
+## Comment puis-je tester le plugin et que signifient les options des commandes ?
+
+Une fois le plugin installé, vous pouvez tester celui-ci directement en ligne
+de commande depuis votre collecteur Centreon en vous connectant avec
+l'utilisateur **centreon-engine** (`su - centreon-engine`). Vous pouvez tester
+que le connecteur arrive bien à superviser une ressource en utilisant une commande
+telle que celle-ci (remplacez les valeurs d'exemple par les vôtres) :
```bash
/usr/lib/centreon/plugins/centreon_viptela_snmp.pl \
- --plugin=network::viptela::snmp::plugin \
- --mode=cpu \
- --hostname='10.0.0.1' \
- --snmp-version='2c' \
- --snmp-community='my-snmp-community' \
- --warning-cpu-utilization='' \
- --critical-cpu-utilization='' \
- --verbose
+ --plugin=network::viptela::snmp::plugin \
+ --mode=gre-tunnels \
+ --hostname='10.0.0.1' \
+ --snmp-version='2c' \
+ --snmp-community='my-snmp-community' \
+ --filter-dest-ip='' \
+ --filter-src-ip='' \
+ --warning-status='' \
+ --critical-status='%{adminState} eq "up" and %{operState} ne "up"' \
+ --warning-gretunnels-detected='' \
+ --critical-gretunnels-detected='' \
+ --warning-gretunnels-up='' \
+ --critical-gretunnels-up='' \
+ --warning-gretunnels-down='' \
+ --critical-gretunnels-down='' \
+ --warning-gretunnels-invalid='' \
+ --critical-gretunnels-invalid='' \
+ --warning-gretunnel-packets-in='' \
+ --critical-gretunnel-packets-in='' \
+ --warning-gretunnel-packets-out='' \
+ --critical-gretunnel-packets-out='' \
+ --verbose
```
La commande devrait retourner un message de sortie similaire à :
```bash
-OK: Cpu utilization: 95.00% | 'cpu.utilization.percentage'=95%;;;0;100
+OK: detected: 74108 up: 60368 down: 37577 invalid: 92968 in: 17527 out: 47953 | 'gre_tunnels.detected.count'=74108;;;0; 'gre_tunnels.operational.up.count'=60368;;;0; 'gre_tunnels.operational.down.count'=37577;;;0; 'gre_tunnels.operational.invalid.count'=92968;;;0; 'tunnels~gre_tunnel.packets.in.count'=17527;;;; 'tunnels~gre_tunnel.packets.out.count'=47953;;;;
```
-La liste de toutes les options complémentaires et leur signification peut être
-affichée en ajoutant le paramètre `--help` à la commande:
+### Diagnostic des erreurs communes
-```bash
-/usr/lib/centreon/plugins/centreon_viptela_snmp.pl \
- --plugin=network::viptela::snmp::plugin \
- --mode=cpu \
- --help
- ```
+Rendez-vous sur la [documentation dédiée](../getting-started/how-to-guides/troubleshooting-plugins.md)
+pour le diagnostic des erreurs communes des plugins Centreon.
+
+### Modes disponibles
+
+Dans la plupart des cas, un mode correspond à un modèle de service. Le mode est renseigné dans la commande d'exécution
+du connecteur. Dans l'interface de Centreon, il n'est pas nécessaire de les spécifier explicitement, leur utilisation est
+implicite dès lors que vous utilisez un modèle de service. En revanche, vous devrez spécifier le mode correspondant à ce
+modèle si vous voulez tester la commande d'exécution du connecteur dans votre terminal.
-Tous les modes disponibles peuvent être affichés en ajoutant le paramètre
-`--list-mode` à la commande:
+Tous les modes disponibles peuvent être affichés en ajoutant le paramètre
+`--list-mode` à la commande :
```bash
/usr/lib/centreon/plugins/centreon_viptela_snmp.pl \
- --plugin=network::viptela::snmp::plugin \
- --list-mode
- ```
+ --plugin=network::viptela::snmp::plugin \
+ --list-mode
+```
-### Diagnostic des erreurs communes
+Le plugin apporte les modes suivants :
+
+| Mode | Modèle de service associé |
+|:--------------------------------------------------------------------------------------------------------------------------------------------|:--------------------------------------------|
+| control-connections [[code](https://github.com/centreon/centreon-plugins/blob/develop/src/network/viptela/snmp/mode/controlconnections.pm)] | Net-Viptela-Control-Connections-SNMP-custom |
+| cpu [[code](https://github.com/centreon/centreon-plugins/blob/develop/src/network/viptela/snmp/mode/cpu.pm)] | Net-Viptela-Cpu-SNMP-custom |
+| disk [[code](https://github.com/centreon/centreon-plugins/blob/develop/src/network/viptela/snmp/mode/disk.pm)] | Net-Viptela-Disk-SNMP-custom |
+| gre-tunnels [[code](https://github.com/centreon/centreon-plugins/blob/develop/src/network/viptela/snmp/mode/gretunnels.pm)] | Net-Viptela-Gre-Tunnels-SNMP-custom |
+| hardware [[code](https://github.com/centreon/centreon-plugins/blob/develop/src/network/viptela/snmp/mode/hardware.pm)] | Net-Viptela-Hardware-SNMP-custom |
+| interfaces [[code](https://github.com/centreon/centreon-plugins/blob/develop/src/network/viptela/snmp/mode/interfaces.pm)] | Net-Viptela-Interfaces-SNMP-custom |
+| list-gre-tunnels [[code](https://github.com/centreon/centreon-plugins/blob/develop/src/network/viptela/snmp/mode/listgretunnels.pm)] | Used for service discovery |
+| list-interfaces [[code](https://github.com/centreon/centreon-plugins/blob/develop/src/snmp_standard/mode/listinterfaces.pm)] | Used for service discovery |
+| memory [[code](https://github.com/centreon/centreon-plugins/blob/develop/src/network/viptela/snmp/mode/memory.pm)] | Net-Viptela-Memory-SNMP-custom |
+| uptime [[code](https://github.com/centreon/centreon-plugins/blob/develop/src/network/viptela/snmp/mode/uptime.pm)] | Net-Viptela-Uptime-SNMP-custom |
+
+### Options disponibles
+
+#### Options génériques
+
+Les options génériques sont listées ci-dessous :
+
+| Option | Description |
+|:-------------------------------------------|:---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| --mode | Define the mode in which you want the plugin to be executed (see --list-mode). |
+| --dyn-mode | Specify a mode with the module's path (advanced). |
+| --list-mode | List all available modes. |
+| --mode-version | Check minimal version of mode. If not, unknown error. |
+| --version | Return the version of the plugin. |
+| --pass-manager | Define the password manager you want to use. Supported managers are: environment, file, keepass, hashicorpvault and teampass. |
+| --hostname | Name or address of the host to monitor (mandatory). |
+| --snmp-community | SNMP community (default value: public). It is recommended to use a read-only community. |
+| --snmp-version | Version of the SNMP protocol. 1 for SNMP v1 (default), 2 for SNMP v2c, 3 for SNMP v3. |
+| --snmp-port | UDP port to send the SNMP request to (default: 161). |
+| --snmp-timeout | Time to wait before sending the request again if no reply has been received, in seconds (default: 1). See also --snmp-retries. |
+| --snmp-retries | Maximum number of retries (default: 5). |
+| --maxrepetitions | Max repetitions value (default: 50) (only for SNMP v2 and v3). |
+| --subsetleef | How many OID values per SNMP request (default: 50) (for get\_leef method. Be cautious when you set it. Prefer to let the default value). |
+| --snmp-autoreduce | Progressively reduce the number of requested OIDs in bulk mode. Use it in case of SNMP errors (by default, the number is divided by 2). |
+| --snmp-force-getnext | Use SNMP getnext function in SNMP v2c and v3. This will request one OID at a time. |
+| --snmp-cache-file | Use SNMP cache file. |
+| --snmp-username | SNMP v3 only: User name (securityName). |
+| --authpassphrase | SNMP v3 only: Pass phrase hashed using the authentication protocol defined in the --authprotocol option. |
+| --authprotocol | SNMP v3 only: Authentication protocol: MD5\|SHA. Since net-snmp 5.9.1: SHA224\|SHA256\|SHA384\|SHA512. |
+| --privpassphrase | SNMP v3 only: Privacy pass phrase (privPassword) to encrypt messages using the protocol defined in the --privprotocol option. |
+| --privprotocol | SNMP v3 only: Privacy protocol (privProtocol) used to encrypt messages. Supported protocols are: DES\|AES and since net-snmp 5.9.1: AES192\|AES192C\|AES256\|AES256C. |
+| --contextname | SNMP v3 only: Context name (contextName), if relevant for the monitored host. |
+| --contextengineid | SNMP v3 only: Context engine ID (contextEngineID), if relevant for the monitored host, given as a hexadecimal string. |
+| --securityengineid | SNMP v3 only: Security engine ID, given as a hexadecimal string. |
+| --snmp-errors-exit | Expected status in case of SNMP error or timeout. Possible values are warning, critical and unknown (default). |
+| --snmp-tls-transport | Transport protocol for TLS communication (can be: 'dtlsudp', 'tlstcp'). |
+| --snmp-tls-our-identity | X.509 certificate to identify ourselves. Can be the path to the certificate file or its contents. |
+| --snmp-tls-their-identity | X.509 certificate to identify the remote host. Can be the path to the certificate file or its contents. This option is unnecessary if the certificate is already trusted by your system. |
+| --snmp-tls-their-hostname | Common Name (CN) expected in the certificate sent by the host if it differs from the value of the --hostname parameter. |
+| --snmp-tls-trust-cert | A trusted CA certificate used to verify a remote host's certificate. If you use this option, you must also define --snmp-tls-their-hostname. |
+| --verbose | Display extended status information (long output). |
+| --debug | Display debug messages. |
+| --filter-perfdata | Filter perfdata that match the regexp. Example: adding --filter-perfdata='avg' will remove all metrics that do not contain 'avg' from performance data. |
+| --filter-perfdata-adv | Filter perfdata based on a "if" condition using the following variables: label, value, unit, warning, critical, min, max. Variables must be written either %{variable} or %(variable). Example: adding --filter-perfdata-adv='not (%(value) == 0 and %(max) eq "")' will remove all metrics whose value equals 0 and that don't have a maximum value. |
+| --explode-perfdata-max | Create a new metric for each metric that comes with a maximum limit. The new metric will be named identically with a '\_max' suffix). Example: it will split 'used\_prct'=26.93%;0:80;0:90;0;100 into 'used\_prct'=26.93%;0:80;0:90;0;100 'used\_prct\_max'=100%;;;; |
+| --change-perfdata --extend-perfdata | Change or extend perfdata. Syntax: --extend-perfdata=searchlabel,newlabel,target\[,\[newuom\],\[min\],\[max\]\] Common examples: =over 4 Convert storage free perfdata into used: --change-perfdata='free,used,invert()' Convert storage free perfdata into used: --change-perfdata='used,free,invert()' Scale traffic values automatically: --change-perfdata='traffic,,scale(auto)' Scale traffic values in Mbps: --change-perfdata='traffic\_in,,scale(Mbps),mbps' Change traffic values in percent: --change-perfdata='traffic\_in,,percent()' =back |
+| --change-perfdata | Change or extend perfdata. Syntax: --extend-perfdata=searchlabel,newlabel,target\[,\[newuom\],\[min\],\[max\]\] Common examples: =over 4 Convert storage free perfdata into used: --change-perfdata='free,used,invert()' Convert storage free perfdata into used: --change-perfdata='used,free,invert()' Scale traffic values automatically: --change-perfdata='traffic,,scale(auto)' Scale traffic values in Mbps: --change-perfdata='traffic\_in,,scale(Mbps),mbps' Change traffic values in percent: --change-perfdata='traffic\_in,,percent()' =back |
+| --extend-perfdata | Change or extend perfdata. Syntax: --extend-perfdata=searchlabel,newlabel,target\[,\[newuom\],\[min\],\[max\]\] Common examples: =over 4 Convert storage free perfdata into used: --change-perfdata='free,used,invert()' Convert storage free perfdata into used: --change-perfdata='used,free,invert()' Scale traffic values automatically: --change-perfdata='traffic,,scale(auto)' Scale traffic values in Mbps: --change-perfdata='traffic\_in,,scale(Mbps),mbps' Change traffic values in percent: --change-perfdata='traffic\_in,,percent()' =back |
+| --extend-perfdata-group | Add new aggregated metrics (min, max, average or sum) for groups of metrics defined by a regex match on the metrics' names. Syntax: --extend-perfdata-group=regex,namesofnewmetrics,calculation\[,\[newuom\],\[min\],\[max\]\] regex: regular expression namesofnewmetrics: how the new metrics' names are composed (can use $1, $2... for groups defined by () in regex). calculation: how the values of the new metrics should be calculated newuom (optional): unit of measure for the new metrics min (optional): lowest value the metrics can reach max (optional): highest value the metrics can reach Common examples: =over 4 Sum wrong packets from all interfaces (with interface need --units-errors=absolute): --extend-perfdata-group=',packets\_wrong,sum(packets\_(discard\|error)\_(in\|out))' Sum traffic by interface: --extend-perfdata-group='traffic\_in\_(.*),traffic\_$1,sum(traffic\_(in\|out)\_$1)' =back |
+| --change-short-output --change-long-output | Modify the short/long output that is returned by the plugin. Syntax: --change-short-output=pattern~replacement~modifier Most commonly used modifiers are i (case insensitive) and g (replace all occurrences). Example: adding --change-short-output='OK~Up~gi' will replace all occurrences of 'OK', 'ok', 'Ok' or 'oK' with 'Up' |
+| --change-short-output | Modify the short/long output that is returned by the plugin. Syntax: --change-short-output=pattern~replacement~modifier Most commonly used modifiers are i (case insensitive) and g (replace all occurrences). Example: adding --change-short-output='OK~Up~gi' will replace all occurrences of 'OK', 'ok', 'Ok' or 'oK' with 'Up' |
+| --change-long-output | Modify the short/long output that is returned by the plugin. Syntax: --change-short-output=pattern~replacement~modifier Most commonly used modifiers are i (case insensitive) and g (replace all occurrences). Example: adding --change-short-output='OK~Up~gi' will replace all occurrences of 'OK', 'ok', 'Ok' or 'oK' with 'Up' |
+| --change-exit | Replace an exit code with one of your choice. Example: adding --change-exit=unknown=critical will result in a CRITICAL state instead of an UNKNOWN state. |
+| --range-perfdata | Rewrite the ranges displayed in the perfdata. Accepted values: 0: nothing is changed. 1: if the lower value of the range is equal to 0, it is removed. 2: remove the thresholds from the perfdata. |
+| --filter-uom | Mask the units when they don't match the given regular expression. |
+| --opt-exit | Replace the exit code in case of an execution error (i.e. wrong option provided, SSH connection refused, timeout, etc). Default: unknown. |
+| --output-ignore-perfdata | Remove all the metrics from the service. The service will still have a status and an output. |
+| --output-ignore-label | Remove the status label ("OK:", "WARNING:", "UNKNOWN:", CRITICAL:") from the beginning of the output. Example: 'OK: Ram Total:...' will become 'Ram Total:...' |
+| --output-xml | Return the output in XML format (to send to an XML API). |
+| --output-json | Return the output in JSON format (to send to a JSON API). |
+| --output-openmetrics | Return the output in OpenMetrics format (to send to a tool expecting this format). |
+| --output-file | Write output in file (can be combined with json, xml and openmetrics options). E.g.: --output-file=/tmp/output.txt will write the output in /tmp/output.txt. |
+| --disco-format | Applies only to modes beginning with 'list-'. Returns the list of available macros to configure a service discovery rule (formatted in XML). |
+| --disco-show | Applies only to modes beginning with 'list-'. Returns the list of discovered objects (formatted in XML) for service discovery. |
+| --float-precision | Define the float precision for thresholds (default: 8). |
+| --source-encoding | Define the character encoding of the response sent by the monitored resource Default: 'UTF-8'. =head1 DESCRIPTION B\