.PAGE 'LCC.INIT'
;
;
;
; INITIALIZATION OF CONTROLLER
;
;
;
CNTINT LDA #%01101111 ; DATA DIRECTION
STA DDRB2
AND #$FF-$08-$04-$03 ; TURN MOTOR OFF,SET PHASE A, LED OFF
STA DSKCNT
;
;
LDA PCR2 ; SET EDGE AND LATCH MODE
AND #$FF-$01 ; NEG EDGE PLEASE
;
;
; CA2: SOE OUTPUT HI DISABLE S.O. INTO 6502
;
ORA #$0E
;
;
; CB1 INPUT ONLY
;
; CB2 MODE CONTROL R/W
;
ORA #$E0
STA PCR2
;
;
LDA #$41 ; CONT IRQ, LATCH MODE
STA ACR2
;
LDA #0
STA T1LL2
LDA #TIM ; 20 MS /IRQ
STA T1HL2
STA T1HC2 ; GET 6522'S ATTENTION
;
LDA #$7F ; CLEAR ALL IRQ SOURCES
STA IER2
;
LDA #$80+$40
STA IFR2 ; CLEAR BIT
STA IER2 ; ENABLE IRQ
;
;
LDA #$FF ; NO CURRENT DRIVE
STA CDRIVE
STA FTNUM ; INIT FORMAT FLAG
;
LDA #$08 ; HEADER BLOCK ID
STA HBID
;
LDA #$07 ; DATA BLOCK ID
STA DBID
;
LDA #<INACT
STA NXTST
LDA #>INACT
STA NXTST+1
;
LDA #200
STA MINSTP
;
LDA #4
STA AS
;
LDA #$4
STA AF
;
.END