emonHub is configured with emonhub.conf
config file. On the emonPi / emonBase this file is located in the R/W data partition /home/pi/data/emonhub.conf
. If the Emoncms Config module is installed (as in the case of the emonPi / emonBase using pre-buit SD card image) the config file can be edited direct from the EmonHub tab in local Emoncms, see User Guide
Emonhub.conf has 3 sections:
Hub is a section for emonhub global settings such as the loglevel.
Interfacers holds the configuration for the different interfacers that emonhub supports such as the EmonHubJeeInterfacer for reading and writing to the RFM69Pi adapter board or emonPi board via serial, or the EmonHubMqttInterfacer which can be used to publish the data received from EmonHubJeeInterfacer to MQTT topics. For more interfacer examples see conf/interfacer_examples
Nodes holds the decoder configuration for rfm12/69 node data which are sent as binary structures.
#######################################################################
####################### emonhub.conf #########################
#######################################################################
### emonHub configuration file, for info see documentation:
### https://github.com/openenergymonitor/emonhub/blob/emon-pi/conf/emonhub.conf
#######################################################################
####################### emonHub settings #######################
#######################################################################
[hub]
### loglevel must be one of DEBUG, INFO, WARNING, ERROR, and CRITICAL
loglevel = DEBUG
#######################################################################
####################### Interfacers #######################
#######################################################################
[interfacers]
#######################################################################
####################### Nodes #######################
#######################################################################
[nodes]
View full latest default emonHub.conf
Hub is a section for emonhub global settings such as the loglevel.
The hub configuration should be self explanatory. Emonhub log can be viewed in the Setup > EmonHub
section of local Emoncms on an emonPi / emonBase. Default settings are:
### loglevel must be one of DEBUG, INFO, WARNING, ERROR, and CRITICAL
loglevel = DEBUG
### Uncomment this to also send to syslog
# use_syslog = yes
Interfacers holds the configuration for the different interfacers that emonhub supports such as the EmonHubJeeInterfacer for reading and writing to the RFM69Pi adapter board or emonPi board via serial, or the EmonHubMqttInterfacer which can be used to publish the data received from EmonHubJeeInterfacer to MQTT topics:
The [[RFM2Pi]]
interfacer section contains the settings to read from RFM69Pi / emonPi boards via GPIO internal serial port /dev/ttyAMA0
. The default serial baud on all emonPi and RFM69Pi is 38400
. Older RFM12Pi boards using 9600
baud.
The frequency and network group must match the hardware and other nodes on the network.
The calibration
config is used to set the calibration of the emonPi when using USA AC-AC adapters 110V. Set calibration = 110V
when using USA AC-AC adapter.
[[RFM2Pi]]
Type = EmonHubJeeInterfacer
[[[init_settings]]]
com_port = /dev/ttyAMA0
com_baud = 38400 # 9600 for old RFM12Pi
[[[runtimesettings]]]
pubchannels = ToEmonCMS,
subchannels = ToRFM12,
group = 210
frequency = 433
baseid = 5 # emonPi / emonBase nodeID
quiet = true # Report incomplete RF packets (no implemented on emonPi)
calibration = 230V # (UK/EU: 230V, US: 110V)
# interval = 0 # Interval to transmit time to emonGLCD (seconds)
Emonhub supports publishing to MQTT topics through the EmonHubMqttInterfacer, defined in the interfacers section of emonhub.conf.
There are two formats that can be used for publishing node data to MQTT:
(default base topic is emonhub
)
topic: basetopic/rx/10/values
payload: 100,200,300
The 'node only format' is used with the emoncms Nodes Module (now deprecated on Emoncms V9) and the emonPiLCD python service.
(default base topic is emon
)
topic: basetopic/emontx/power1
payload: 100
The 'Node variable format' is the current default format on Emoncms V9. It's a more generic MQTT publishing format that can more easily be used by applications such as NodeRED and OpenHab. This format can also be used with the emoncms phpmqtt_input.php
script in conjunction with the emoncms inputs module. See User Guide > Technical MQTT.
Default [MQTT]
config:
[[MQTT]]
Type = EmonHubMqttInterfacer
[[[init_settings]]]
mqtt_host = 127.0.0.1
mqtt_port = 1883
mqtt_user = emonpi
mqtt_passwd = emonpimqtt2016
[[[runtimesettings]]]
pubchannels = ToRFM12,
subchannels = ToEmonCMS,
# emonhub/rx/10/values format
# Use with emoncms Nodes module
node_format_enable = 1
node_format_basetopic = emonhub/
# emon/emontx/power1 format - use with Emoncms MQTT input
# http://github.com/emoncms/emoncms/blob/master/docs/RaspberryPi/MQTT.md
nodevar_format_enable = 1
nodevar_format_basetopic = emon/
To enable the node variable format set nodevar_format_enable = 1
. To disable the node only format set node_format_enable = 0
.
The EmonHubEmoncmsHTTPInterfacer configuration that is used for sending data to emoncms.org can also be found in the interfacers section of emonhub.conf. If you wish to use emoncms.org the only change to make here is to replace the blank apikey with your write apikey from emoncms.org found on the user account page. See Setup Guide > Setup > Remote logging.
[[emoncmsorg]]
Type = EmonHubEmoncmsHTTPInterfacer
[[[init_settings]]]
[[[runtimesettings]]]
pubchannels = ToRFM12,
subchannels = ToEmonCMS,
url = https://emoncms.org
apikey = xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
senddata = 1
sendstatus = 1
sendstatus Its possible to the EmonHubEmoncmsHTTPInterfacer to send a 'ping' to the destination emoncms that can be picked up by the myip module which will then list the source IP address. This can be useful for remote login to an home emonpi if port forwarding is enabled on your router.
senddata If you only want to send the ping request and no data to emoncms.org set this to 0
You can create multiple of these sections to send data to multiple emoncms instances. For example, if you wanted to send to an emoncms running at emoncms.example.com you would add the following underneath the emoncmsorg
section described above:
[[emoncmsexample]]
Type = EmonHubEmoncmsHTTPInterfacer
[[[init_settings]]]
[[[runtimesettings]]]
pubchannels = ToRFM12,
subchannels = ToEmonCMS,
url = https://emoncms.example.com
apikey = xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
senddata = 1
sendstatus = 1
This time, the API key will be the API key from your account at emoncms.example.com.
The EmonHub socket interfacer is a particularly useful interfacer for inputing data from a range of sources. e.g a script monitoring server status where you wish to post the result to both a local instance of emoncms and a remote instance of emoncms alongside other data from other sources such as rfm node data.
As an example the following python script will post a single line of data values on node 98 to an emonhub instance running locally and listening on port 8080:
import socket, time
s = socket.socket(socket.AF_INET, socket.SOCK_STREAM)
s.connect(('localhost', 8080))
s.sendall('98 3.8 1.6 5.2 80.3\r\n')
The following emonhub.conf interfacer definition will listen on the choosen socket and forward the data on the ToEmonCMS channel:
[[mysocketlistener]]
Type = EmonHubSocketInterfacer
[[[init_settings]]]
port_nb = 8080
[[[runtimesettings]]]
pubchannels = ToEmonCMS,
To set a timestamp for the posted data add the timestamped property to the emonhub.conf runtimesettings section:
[[[runtimesettings]]]
pubchannels = ToEmonCMS,
timestamped = True
The python client example needs to include the timestamp e.g:
s.sendall(str(time.time())+' 98 3.8 1.6 5.2 80.3\r\n')
The 2nd part of the emonhub.conf configuration concerns decoding of RFM12 and RFM69 nodes. Here's an example of what this section looks like from the default emonpi emonhub.conf. The rest of this readme explains what each line means and how to write your own node decoders or adapt existing decoders for new requirements.
#######################################################################
####################### Nodes #######################
#######################################################################
[nodes]
### List of nodes by node ID
### 'datacode' is default for node and 'datacodes' are per value data codes.
### if both are present 'datacode' is ignored in favour of 'datacodes'
### eg node 99 would expect 1 long and 4 ints, unless the "datacodes" line
### was removed, then "datacode" would make it expect any number of longs,
### likewise per value "scales" will override default node "scale"
[[5]]
nodename = emonPi
firmware = emonPi_RFM69CW_RF12Demo_DiscreteSampling.ino
hardware = emonpi
[[[rx]]]
names = power1,power2,power1_plus_power2,Vrms,T1,T2,T3,T4,T5,T6,pulseCount
datacodes = h, h, h, h, h, h, h, h, h, h, L
scales = 1,1,1,0.01,0.1,0.1,0.1,0.1,0.1,0.1,1
units = W,W,W,V,C,C,C,C,C,C,p
[[10]]
A numeric NodeID. This identifies the node to emonHub, and every node within your system must have a unique ID. There may be only one definition for each NodeId. The NodeID is programmed into the node firmware, either in the sketch and/or by switches.
`nodename =`
A text string, for your benefit in identifying each node. This field is optional.
MQTT: The nodename can be used with the MQTT interfacer to send topics of the form nodes/nodename/variablename.
`firmware =`
A text string specifying the sketch running on the node. (At present, this is for information only. At some future time, it might be used to auto-configure emonHub and/or the sketch.) This field is optional.
`hardware =`
Indicates the host environment for human reference. This field is optional.
`[[[rx]]]`
This must be "rx" and specifies that the next section is for the config of the sensor values received from a node. Its also possible to define a "tx" section for variables to be sent to the node such as control state's. Documentation on this to be added.
An un-configured Emonhub will by default assume that RFM12 or RFM69 data packets received are a series of integers, each 2 bytes long. The radio packet format is quite minimal and non-descriptive and so emonhub cant know how to decode the packets from the received data if the packet structure is any different.
Earlier OpenEnergyMonitor nodes always sent a series of integers and so no decoder configuration was needed, more recent revisions now include the sending of pulse counts or watt hours which would overrun the maximum value that can be sent as an integer. The latest EmonPi, EmonTx3 and EmonTH firmware's all send pulse count as long datatypes at the end of their packets taking up 4 bytes.
Its possible to decode any radio packet that is packed as a binary structure with Emonhub. For example if we look at the relevant part of the node decoder for the emontx v3 we can see 11 integers (h) and one unsigned long at the end (L)
[[8]]
[[[rx]]]
datacodes = h,h,h,h,h,h,h,h,h,h,h,L
The node decoder could be left as this if we only wanted to decode the packet structure correctly. Alternatively if the packet structure is a series of integers its possible to write:
[[1]]
[[[rx]]]
datacode = h
Notice that the name is datacode rather than datacodes with an s. There are 13 different datatypes that can be decoded:
b: byte, 1 byte
h: short integer, 2 bytes
i: integer, 4 bytes
l: long, 4 bytes
q: long long, 8 bytes
f: float, 4 bytes
d: double, 8 bytes
B: unsigned byte, 1 byte
H: unsigned integer, 2 bytes
I: unsigned integer, 4 bytes
L: unsigned long, 4 bytes
Q: unsigned long long, 8 bytes
c: char, 1 byte
Note: Arduino integers are 2 bytes long and so we use the short integer decoder: h.
It's possible to specify sensor value names to help with identification. The emoncms nodes module can also load these names for its node list. Another possibility not yet implemented is to use these names to publish sensor values to MQTT topics of the form nodes/emontx/power1.
[[8]]
[[[rx]]]
names = power1, power2, power3, power4, Vrms, temp1, temp2, temp3, temp4, temp5, temp6, pulse
datacodes = h,h,h,h,h,h,h,h,h,h,h,L
In order to keep radio packet length small a sensor value measured as a float on an emontx or emonth (i.e temperature) is first multiplied by 10x or 100x, then sent as a 2-byte integer in the radio packet and then scaled back to the original value on receipt in emonhub. This saves 2 bytes per sensor value and provides a convenient way of providing 1 or 2 decimal place resolution.
The scales to be applied can either be specified for each sensor value as in this example for the emontx:
[[8]]
[[[rx]]]
names = power1, power2, power3, power4, Vrms, temp1, temp2, temp3, temp4, temp5, temp6, pulse
datacodes = h,h,h,h,h,h,h,h,h,h,h,L
scales = 1,1,1,1,0.01,0.1,0.1,0.1,0.1,0.1,0.1,1
In this example the RMS Voltage is multiplied by 0.01 and temperature values by 0.1. Which means that the RMS voltage was multiplied by 100x and temperature values by 10x on the emontx.
or a single scale can be applied (note scale instead of scales with an s)
[[8]]
[[[rx]]]
datacodes = h,h,h,h,h,h,h,h,h,h,h,L
scale = 1
The default scale value is 1 and so in the scale where no scaling is needed this line can be left out of the configuration.
The latest version of the emon-pi variant of emonhub does not require the number of scales to match the number of variables, it will scale according to the scales available or scale by 1 if scales are not available.
A comma-separated list of engineering units to describe the data. Common units are W, kW, V, A, C, %. These are only to help with identification. The are currently made use of in the emoncms nodes module UI.
[[8]]
[[[rx]]]
names = power1, power2, power3, power4, Vrms, temp1, temp2, temp3, temp4, temp5, temp6, pulse
datacodes = h,h,h,h,h,h,h,h,h,h,h,L
scales = 1,1,1,1,0.01,0.1,0.1,0.1,0.1,0.1,0.1,1
units =W,W,W,W,V,C,C,C,C,C,C,p
The following lists the standard node decoders for recent versions of the EmonPi, EmonTx v3, EmonTH and EmonTxShield. These are currently included in emonhub.conf and provide automatic decoding of node data.
If you upload the firmware yourself to any of these nodes and wish to have the data decoded with names, units and scaled correctly these are the decoders for the standard firmwares. The node decoders are also included at the top of each firmware file for reference.
EmonPi:Firmware location
Copied here for reference:
[[5]]
nodename = emonPi
firmware = emonPi_RFM69CW_RF12Demo_DiscreteSampling.ino
hardware = emonpi
[[[rx]]]
names = power1,power2,power1_plus_power2,Vrms,T1,T2,T3,T4,T5,T6,pulseCount
datacodes = h, h, h, h, h, h, h, h, h, h, L
scales = 1,1,1,0.01,0.1,0.1,0.1,0.1,0.1,0.1,1
units = W,W,W,V,C,C,C,C,C,C,p
EmonTx v3: Firmware location
Node ID when DIP switch1 is off = 8, node ID when DIP switch1 is on is 7
Copied here for reference:
[[8]]
nodename = emonTx_3
firmware =V2_3_emonTxV3_4_DiscreteSampling
hardware = emonTx_(NodeID_DIP_Switch1:OFF)
[[[rx]]]
names = power1, power2, power3, power4, Vrms, temp1, temp2, temp3, temp4, temp5, temp6, pulse
datacodes = h,h,h,h,h,h,h,h,h,h,h,L
scales = 1,1,1,1,0.01,0.1,0.1, 0.1,0.1,0.1,0.1,1
units =W,W,W,W,V,C,C,C,C,C,C,p
EmonTx v3, emonTxV3_4_DiscreteSampling.ino, v1.6+ Firmware Location
Can be on either nodeid 10 or 9
[[10]]
nodename = emonTx_1
firmware =V1_6_emonTxV3_4_DiscreteSampling
hardware = emonTx_(NodeID_DIP_Switch1:OFF)
[[[rx]]]
names = power1, power2, power3, power4, Vrms, temp1, temp2, temp3, temp4, temp5, temp6, pulse
datacode = h
scales = 1,1,1,1,0.01,0.1,0.1, 0.1,0.1,0.1,0.1,1 #Firmware V1.6
units =W,W,W,W,V,C,C,C,C,C,C,p
[[10]]
nodename = emonTx_1
firmware =V1_6_emonTxV3_4_DiscreteSampling
hardware = emonTx_(NodeID_DIP_Switch1:OFF)
[[[rx]]]
names = power1, power2, power3, power4, Vrms, temp
datacode = h
scales = 1,1,1,1,0.01,0.1
units =W,W,W,W,V,C
EmonTH V2: Firmware location
Standard nodeid's: 23, 24, 25 & 26 depending on DIP switch positions:
[[23]]
nodename = emonTH_5
firmware = V2.x_emonTH_DHT22_DS18B20_RFM69CW_Pulse
hardware = emonTH_(Node_ID_Switch_DIP1:OFF_DIP2:OFF)
[[[rx]]]
names = temperature, external temperature, humidity, battery, pulseCount
datacodes = h,h,h,h,L
scales = 0.1,0.1,0.1,0.1,1
units = C,C,%,V,p
emonTH V1 Firmware location
Standard nodeid's: 19, 20, 21 & 22 depending on DIP switch positions:
[[19]]
nodename = emonTH_1
firmware = emonTH_DHT22_DS18B20_RFM69CW
hardware = emonTH_(Node_ID_Switch_DIP1:OFF_DIP2:OFF)
[[[rx]]]
names = temperature, external temperature, humidity, battery
datacode = h
scales = 0.1,0.1,0.1,0.1
units = C,C,%,V
EmonTx Shield [Firmware location]https://github.com/openenergymonitor/emontx-shield)
[[6]]
nodename = emonTxShield
firmware =emonTxShield
hardware = emonTxShield
[[[rx]]]
names = power1, power2, power3, power4, Vrms
datacode = h
scales = 1,1,1,1,0.01
units =W,W,W,W,V
Try replacing the datacodes = h,h,h,h,... line with datacode = h (note: datacode without an s). This will decode most of the radio packet content for the standard OpenEnergyMonitor emontx,emonth and emonpi firmwares, including historic versions.
The EmonTx and EmonTH nodes both have switches on their circuit boards for changing the nodeid to save having to reprogram. Depending on the switch positions and firmware version the EmonTx v3 can be on node 7,8,9 or 10. The EmonTH can be on 19,20,21,22,23,24,25 or 26.