Notifications
You must be signed in to change notification settings - Fork 6
Troubleshooting
Here you can find troubleshooting tips and workarounds for TomoBEAR
.
After processing each module TomoBEAR
puts processing control files SUCCESS
or FAILURE
depending on the outcome of the whole processing step. Additionally, for the modules which process tomograms independently of each other in parallel manner (like CreateStacks
, MotionCor2
, BatchRunTomo
, etc.), inside each tomogram's folder there will be as well SUCCESS
or FAILURE
depending on the outcome of the particular tomogram processing.
SUCCESS files contents
The fileSUCCESS
contains bit (0/1) vector of the number of tomograms length with 0s or 1s meaning failure or success of processing for the corresponding tomogram so that successful ones will be used on the further processing steps. This might be useful to know when you need workaround if something is not working.
If you want to reprocess some particular step(s) or even particular tomogram(s) on certain steps, you need to delete the corresponding SUCCESS
/FAILURE
files, before restarting TomoBEAR
.
If for some reason you don't want to process further a certain tomogram, feel free to put in that tomogram's folder FAILURE
file.
Finally, if you put "tomogram_indices" in "general"
section of the input JSON file and TomoBEAR
still processing all of the tomograms for steps where they are processed independently, you might try to delete SUCCESS
files for couple of previous step folders (but not in tomograms folders and not for steps which don't have tomogram folders, otherwise they would be reprocessed), so that TomoBEAR
will just update its metadata properly.
- In case your input data was collected using dose-symmetric scheme starting from 0-deg-tilt
If that is the case, the raw data files contain both 0.0
and -0.0
tilts, for example, TS_001_0.0_Sep07_19.38.12.tif
and TS_002_-0.0_Sep07_19.52.42.tif
. This happens because physically zero angles are not ideally equal to zero, they are just very small (e.g., -0.0049795). To make sorting right in the described case you may add "first_tilt_angle": 0
to general
section of your input JSON file.
- In case your input data have more than one TS prefix (separated by an underscore '_')
We would recommend you to make symbolic links to the original raw data with a single TS prefix.
An example bash script softlink_files.sh
to change prefix for all files of a single tilt serie in TIF
data format is provided below:
prefix_to_cut=${1}
prefix_to_put=${2}
dir_data_raw=$(readlink -f ./${3})
dir_data_links=$(readlink -f ./${4})
for file_tif_old in ${dir_data_raw}/${prefix_to_cut}*.tif ; do
file_tif_trunc=${file_tif_old#*${prefix_to_cut}}
file_mdoc_old=${file_tif_old}.mdoc
file_tif_new=${dir_data_links}/${prefix_to_put}$file_tif_trunc
file_mdoc_new=${file_tif_new}.mdoc
echo 'Linking ' $file_tif_old ' to ' $file_tif_new
ln -s $file_tif_old $file_tif_new
echo 'Linking ' $file_mdoc_old ' to ' $file_mdoc_new
ln -s $file_mdoc_old $file_mdoc_new
done
You may use the script above softlink_files.sh
to rename input data as softlinks to original files as the following:
softlink_files.sh PREFIX1_PREFIX2_PREFIX3_ PREFIXNEW_ original/dir/path renamed/dir/path
where for each TIF
file in the location original/dir/path
a set of prefixes PREFIX1_PREFIX2_PREFIX3_
will be substituted with a single prefix PREFIXNEW_
and softlinks with the new filenames to the corresponding original files will be saved in the renamed/dir/path
directory.
If you are running the module in parallel execution mode set the parameter "execution_method"
in the DynamoTiltSeriesAlignment
block to "sequential"
. Then the execution will be slower because only one tilt stack will be processed at a time but the memory consumption will be less.
This usually happens at low binning values (e.g., bin2 or bin1). You may put additional parameter "dt_crop_in_memory": 0
to the corresponding DynamoAlignmentProject
sections in order to prevent keeping the whole tomogram in the memory during processing. This will slow down processing because Dynamo
will read tomogram volume several times but the memory consumption will be less.