This algorithm aims at rejecting decays with photons at large angle and inelastic interactions.
The algorithm uses all LAV stations and corresponds to a cut on the number of LAV hits in time with respect to the L0 trigger.
The cut tested on 2014 data (run 1520) is: Nhits < 2 (see pag 25 here).
The algorithm efficiently rejects pipi0 with photon(s) at large angle.