Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathjk_pylon_can.py
executable file
·1107 lines (920 loc) · 48.3 KB
/
jk_pylon_can.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
#!/usr/bin/python3
###############################################################################################
# Purpose: read JK-BMS via UART and send info via can-bus using Pylontech Protocol
##########
#credits go to:
#1) Juamiso, who developed the CAN-BUS Part
#https://github.com/juamiso/PYLON_EMU
#2) PurpleAlien, who developed the JK-UART script
#https://github.com/PurpleAlien/jk-bms_grafana
# Disclaimer
############
# The author is not taking any responsibility for any damage or issue resulting by making use of this project.
# Use at own risk
# platform tested: RPI2 with wavshare canhat
###############################################################################################
# canbus
from __future__ import print_function
import cantools
import time
from binascii import hexlify
import can
can_db="./pylon_CAN_210124.dbc"
#can_db="/home/behn/jk_pylon/pylon_CAN_210124.dbc"
import check_can_up # cheks if can0 interface is UP. if not, its using sudo ip link to bring UP
# JK-stuff
import time
import datetime
import sys, os, io
import struct
import serial
import my_read_bms
#hmc5883l sensor to read ampere of Goodwe
import smbus
import my_hmc5883l
import multiprocessing
# round-down via math.floor
import math
#mqtt - for logging-purposes we send some stuff to a mqtt-broker.
# not required to operate this script successful
import my_mqtt
import socket
# self written ringbuffer
from my_basic_ringbuf import myRingBuffer
# ringbuffer
from queue import Queue
import json
# logfile
write_to_file = True # turn only on for debug.
logfile_size = 30 # size im MB, afterwards its reset to zero
log_to_console = False
#filename="./jk_python_can.log"
filename="/mnt/ramdisk/jk_pylon.log"
import logging
import logging.handlers
import os
# goodwe inverter - with two inverters we must avoid then one battery is discharging to allow charging the other one
import sems
# oscillation
#oscillation_enabled_flag=True # requires SMA smartmeter
oscillation_enabled_flag=True
last_monomer_run = 0.0
my_mqtt.meter=Queue()
import print_debug
#read SMA power-meter
import sma_em_capture_package
import my_subprocess_run
sleepTime = 1
def byteArrayToHEX(byte_array):
hex_string = ""
for cmd_byte in byte_array:
hex_byte = ("{0:02x}".format(cmd_byte))
hex_string += hex_byte + " "
return hex_string
def set_discharge_limit(min_volt,Battery_discharge_current_limit,my_soc):
now = time.time()
discharge_limit=Battery_discharge_current_limit
print_debug.my_debug ("discharge_limit when entering set_discharge",Battery_discharge_current_limit)
#mylist=[[3.15,0],[3.20,20],[3.60,60]]
mylist=[[3.15,0],[3.60,60]]
for i in range(len(mylist)):
try:
if (min_volt<=mylist[i][0]):
discharge_limit=mylist[i][1]
print_debug.my_debug("discharge_limit min_volt_check",discharge_limit)
break
except:
discharge_limit=0
print_debug.my_debug("set_discharge_limit_1",discharge_limit)
# making the discharge-limit smaller is always ok
if (discharge_limit<Battery_discharge_current_limit):
Battery_discharge_current_limit=discharge_limit
print_debug.my_debug("set_discharge_limit_2",Battery_discharge_current_limit)
# allowing to increase the discharge-limit
elif (my_soc > 40):
Battery_discharge_current_limit = discharge_limit
print_debug.my_debug("set_discharge_limit_3",discharge_limit)
print_debug.my_debug("set_discharge_limit_4",Battery_discharge_current_limit)
return(Battery_discharge_current_limit)
def set_charge_limit_by_max_monomer(max_volt,Battery_charge_current_limit_set_by_overvolt_protect,my_soc,oscillation_got_detected,timestamp_charge_limit_change_overvolt_protect):
now = time.time()
dbg="set_charge_limit_by_max_monomer"
c_limit=Battery_charge_current_limit_set_by_overvolt_protect
print_debug.my_debug(dbg+"_c_limit_0_overvolt_protect_begin",c_limit)
print_debug.my_debug(dbg+"charge_limit_0",Battery_charge_current_limit_set_by_overvolt_protect)
mylist=[[3.60,0],[3.55,0],[3.47,0],[3.44,0],[3.42,30],[3.39,60],[3.2,60],[2.70,20]]
for i in range(len(mylist)):
try:
if (max_volt>=mylist[i][0]):
c_limit=mylist[i][1]
print_debug.my_debug(dbg+"_c_limit_1",c_limit)
break
except:
c_limit=0
print_debug.my_debug(dbg+"c_limit_2",c_limit)
# making the charge-limit smaller is always ok
if (c_limit<Battery_charge_current_limit_set_by_overvolt_protect):
timestamp_charge_limit_change_overvolt_protect= now
Battery_charge_current_limit_set_by_overvolt_protect=c_limit
print_debug.my_debug(dbg+"c_limit_3",c_limit)
print_debug.my_debug(dbg+"charge_limit_3",Battery_charge_current_limit_set_by_overvolt_protect)
# in case the derived charge-limit is higher then previuos,
# we want to be sure:
# >> only increase if max_volt is save (<3.4Volt)
# >> only increase if SOC < 97%
# wait at least 45min = 2700sec before trying to increase back again
elif ((my_soc <=99) and (max_volt < 3.4 and not oscillation_got_detected) and (now - timestamp_charge_limit_change_overvolt_protect> 2700)):
Battery_charge_current_limit_set_by_overvolt_protect=c_limit
print_debug.my_debug(dbg+"c_limit_4",c_limit)
print_debug.my_debug(dbg+"charge_limit_4",Battery_charge_current_limit_set_by_overvolt_protect)
if False:
#elif (allow_larger_100_percent_soc and max_volt < 3.4 and not oscillation_got_detected and (now - timestamp_charge_limit_change_overvolt_protect> 2700)):
Battery_charge_current_limit_set_by_overvolt_protect=c_limit
print_debug.my_debug(dbg+"c_limit_5",c_limit)
print_debug.my_debug(dbg+"charge_limit_5",Battery_charge_current_limit_set_by_overvolt_protect)
print_debug.my_debug(dbg+"c_limit_6",c_limit)
print_debug.my_debug(dbg+"charge_limit_6",Battery_charge_current_limit_set_by_overvolt_protect)
return(Battery_charge_current_limit_set_by_overvolt_protect, timestamp_charge_limit_change_overvolt_protect)
def populate_sma_ringbuffer_old (meter,meter_ringbuffer_W):
# have in mind, ringbuffer is WATT, not Ampere
limit_min_max=250
limit_average=250
osci_count=3
oscillation_got_detected=False
while not meter.is_empty():
my_message=meter.get()
if my_message is None:
continue
y=json.loads(my_message)
pconsume=y['pconsume']
#print("pconsume", pconsume)
psupply=y['psupply']
#print("psupply", psupply)
add=False
if (pconsume>0):
value=-pconsume
add=True
if (psupply>0):
value=psupply
add=True
if (add):
meter_ringbuffer_W.append(value)
print_debug.my_debug ("meter_ringbuffer_average", f"{meter_ringbuffer_W.average():.0f}")
print_debug.my_debug ("meter_ringbuffer_min", f"{meter_ringbuffer_W.min():.0f}")
print_debug.my_debug ("meter_ringbuffer_max", f"{meter_ringbuffer_W.max():.0f}")
print_debug.my_debug ("meter_ringbuffer_gt_count", f"{meter_ringbuffer_W.gt_count():.0f}")
print_debug.my_debug ("meter_ringbuffer_lt_count", f"{meter_ringbuffer_W.lt_count():.0f}")
# gt_count counts elements in buffer GreaterThen
# lt_count counts elements in buffer LessThen
upper_value= meter_ringbuffer_W.average()+limit_min_max
lower_value= meter_ringbuffer_W.average()-limit_min_max
if (meter_ringbuffer_W.gt_count(upper_value) > osci_count and meter_ringbuffer_W.lt_count(lower_value) > osci_count):
oscillation_got_detected=True
return(oscillation_got_detected,meter_ringbuffer_W)
def populate_sma_ringbuffer (meter,meter_ringbuffer_W):
# have in mind, ringbuffer is WATT, not Ampere
limit_min_max=150
upper_value= limit_min_max
lower_value= -limit_min_max
#limit_average=400
min_event_osci_true=3
oscillation_got_detected=False
meter_ringbuffer_W.append(meter)
print_debug.my_debug ("meter_ringbuffer_average[W]", f"{meter_ringbuffer_W.average():.0f}")
print_debug.my_debug ("meter_ringbuffer_min[W]", f"{meter_ringbuffer_W.min():.0f}")
print_debug.my_debug ("meter_ringbuffer_max[W]", f"{meter_ringbuffer_W.max():.0f}")
print_debug.my_debug ("meter_actual[W]", f"{meter:.0f}")
print_debug.my_debug ("meter_ringbuffer_gt_count", f"{meter_ringbuffer_W.gt_count(upper_value):.0f}")
print_debug.my_debug ("meter_ringbuffer_lt_count", f"{meter_ringbuffer_W.lt_count(lower_value):.0f}")
# gt_count counts elements in buffer GreaterThen
# lt_count counts elements in buffer LessThen
if (meter_ringbuffer_W.gt_count(upper_value) > min_event_osci_true and meter_ringbuffer_W.lt_count(lower_value) > min_event_osci_true):
#if (meter_ringbuffer_W.average() < limit_average and meter_ringbuffer_W.average() > -limit_average):
oscillation_got_detected=True
print_debug.my_debug ("meter_ringbuffer_oscilation_detected", "True")
# flusing the ringbuffer for a clean start
meter_ringbuffer_W.flush()
return(oscillation_got_detected,meter_ringbuffer_W)
def populate_solis_current_ringbuffer (current,current_ringbuffer):
# add actual ampere towards the ringbuffer
current_ringbuffer.append(current)
#print ("current_ringbuffer", current_ringbuffer.get())
return(current_ringbuffer)
#####################################################
# MAIN LOOP: test_periodic_send_with_modifying_data #
#####################################################
def test_periodic_send_with_modifying_data(bus):
global mqtt_client
last_mqtt_run=0.0
mqtt_sent_interval=20
Battery_charge_current_limit = 0
Battery_charge_current_limit_set_by_overvolt_protect= 0
floating_Battery_charge_current_limit = 0
floating_Battery_discharge_current_limit = 0
Battery_discharge_current_limit = 0
Not_to_exceed_discharge_limit=0
timestamp_charge_limit_change = 0.0 # used to allow increase charge-limit back again
timestamp_last_osci_limit_change_run = 0.0 # how ofetn do we want to check oscilattion and REDUCE the limits
timestamp_charge_limit_change_overvolt_protect=0.0
timestamp_sems_triggered_reduce_charge_limit=0.0
generic_interval_5 = 5 # used for JK_BMS_queary and can-bus checking
timestamp_generic_interval_5=0.0
current_max_size=10 # elements in ringbuffer
current_ringbuffer=myRingBuffer(current_max_size) # init/flush the ringbuffer
meter_ringbuffer_W=myRingBuffer(current_max_size) # init/flush the ringbuffer
hmc_ringbuffer_A=myRingBuffer(6) # init/flush the ringbuffer
solis_ringbuffer_A=myRingBuffer(current_max_size) # init/flush the ringbuffer
Battery_charge_voltage_default = 55
Battery_discharge_voltage_default = 50.5
# oscillation detection
oscillation_got_detected=False
oscillation_mqtt_interval=10
oscillation_mqtt_last_run=0.0
oscillation_last_seen = 0.0
use_hmc=True
q_check_can = multiprocessing.Queue()
q_my_read_bms = multiprocessing.Queue()
q_do_auth_and_query = multiprocessing.Queue()
q_sma = multiprocessing.Queue()
bms_read_success=False
can_fail_counter=0
can_up_status = False
# slow start after fresh start
running_since=time.time()
slow_start_charge_limit=0
###############
# HMC5883L - reading ampere of Goodwe
###############
try:
i2c_bus = smbus.SMBus(1)
my_hmc5883l.setup(i2c_bus)
except:
s1="ERROR: HMC5883L not found"
s2="continuing without HMC5883"
print(s1,s2)
print_debug.my_debug(s1,s2)
hmc_success = False
else:
hmc_success = True
###############
# SEMS STUFF
###############
Sems_Flag = True # set this to True if you have a Goodwe-inverter
#Sems_Flag = False # set this to True if you have a Goodwe-inverter
goodwe_enforced_zero_charge =False
goodwe_enforced_zero_discharge=False
if (Sems_Flag):
token=""
uid=""
timestamp=""
expiry=0.0
api="https://eu.semsportal.com/api/" # will be overwritten as part of the get_token
sems_url_oauth="https://www.semsportal.com/api/v2/Common/CrossLogin"
sems_current_ringbuffer_A=myRingBuffer(1) # init the ringbuffer of size 1
last_sems_run=0.0
sems_success=False
# setting up periodic task to send can-bus updates
##################################################
Alive_packet = 0 #counter
#print("Starting to send a message every 1s")
task_tx_Network_alive_msg = bus.send_periodic(msg_tx_Network_alive_msg, 1)
task_tx_Battery_SoC_SoH = bus.send_periodic(msg_tx_Battery_SoC_SoH, 1)
task_tx_Battery_Manufacturer = bus.send_periodic(msg_tx_Battery_Manufacturer, 1)
task_tx_Battery_Request = bus.send_periodic(msg_tx_Battery_Request, 1)
task_tx_Battery_actual_values_UIt = bus.send_periodic(msg_tx_Battery_actual_values_UIt, 1)
task_tx_Battery_limits = bus.send_periodic(msg_tx_Battery_limits, 1)
task_tx_Battery_Error_Warnings = bus.send_periodic(msg_tx_Battery_Error_Warnings, 1)
time.sleep(0.5)
# one time reading the BMS with JOIN-method to init all variables
##################################################################
bms_read_success=False
bms_count=0
while (not bms_read_success and bms_count<=3): # 3 * retry
mp_read_bms = multiprocessing.Process(target=my_read_bms.readBMS, args=(bms,q_my_read_bms,))
mp_read_bms.start()
mp_read_bms.join()
q=q_my_read_bms.get()
my_soc=q[0]
my_volt=q[1]
my_ampere=q[2]
my_temp=q[3]
min_volt=q[4]
max_volt=q[5]
bms_read_success=q[6]
allow_larger_100_percent_soc=q[7]
#print("bms_read_success",bms_read_success)
if (not bms_read_success):
print_debug.my_debug("Status reading the BMS","Fail")
print("Status reading the BMS","Fail")
time.sleep(5) # wait 5seconds before retrying
bms_count=bms_count+1
if (not bms_read_success):
msg="reading the BMS failed. exiting the prog"
sys.exit(msg)
print_debug.my_debug(msg,"exit")
print(msg)
# setting up SMA energy meter
##############################
my_sma_socket=sma_em_capture_package.sma_socket_setup()
###########################################################################################
# main - loop - query the bms, check under/over-volt, updates message for peridic can-task
###########################################################################################
#print("pre Main loop")
while True:
#print("Main loop running")
now=time.time()
# can-bus counter alive packet
#########################
Alive_packet = Alive_packet+1
if Alive_packet >= 4611686018427387904:
Alive_packet = 2
print_debug.my_debug ("------ new run----------------","")
print_debug.my_debug("run", Alive_packet )
#print("Wait timer")
#time.sleep(100)
# check if can0 interface is up
#####################
check_can_join=False
qs=0
if False:
while (not q_check_can.empty()):
result=q_check_can.get(block=True, timeout=1)
print("CAN Interface: ", result)
can_up_status=result[0]
can_fail_counter = result[1]
#print("content can_up_status: ", can_up_status)
#print("content can-fail-counter: ", can_fail_counter)
#print("")
#print("type can_fail-counter:",type(can_fail_counter))
msg="can_fail_counter"
print_debug.my_debug(msg, str(can_fail_counter))
if (now-timestamp_generic_interval_5> generic_interval_5):
check_can_join=True
#mp_check_can = multiprocessing.Process(target=check_can_up.check_can_interface_up_mp,args=(channel,can_fail_counter,q_check_can))
#mp_check_can.start()
can_up_status,can_fail_counter=check_can_up.check_can_interface_up (channel,can_fail_counter)
if (not can_up_status):
msg="Interface " + channel + " can_up_status"
print_debug.my_debug(msg, "DOWN")
time.sleep(1)
if (can_fail_counter > 30):
msg="REBOOTING now becasue can_fail_counter value"
print_debug.my_debug(msg, str(can_fail_counter))
cmd="sudo reboot"
#q_reboot=multiprocessing.Queue()
#my_subprocess_run.run_cmd(cmd,q_reboot)
my_subprocess_run.run_cmd(cmd)
print_debug.my_debug("can "+channel + " can_up_status", can_up_status)
print_debug.my_debug("can_fail_counter", str(can_fail_counter))
# query the BMS
###############
read_bms_join=False # multiprocessing_flag
if (now-timestamp_generic_interval_5> generic_interval_5):
mp_read_bms = multiprocessing.Process(target=my_read_bms.readBMS, args=(bms,q_my_read_bms,))
mp_read_bms.start()
read_bms_join=True # triggers to set join later on
while (not q_my_read_bms.empty()):
bms_read_success=False
q=q_my_read_bms.get()
my_soc=q[0]
my_volt=q[1]
my_ampere=q[2]
my_temp=q[3]
min_volt=q[4]
max_volt=q[5]
bms_read_success=q[6]
allow_larger_100_percent_soc=q[7]
#print("bms_read_success",bms_read_success)
if (not bms_read_success):
print_debug.my_debug("Status reading the BMS","Fail")
print("Status reading the BMS","Fail")
else:
# populate solis ringbuffer_ampere
current_ringbuffer=populate_solis_current_ringbuffer(my_ampere,current_ringbuffer)
print_debug.my_debug("solis_current", my_ampere)
print("bms done")
# query SMA meter
#################
mp_sma = multiprocessing.Process(target=sma_em_capture_package.sma_socket_decode,args=(my_sma_socket,q_sma))
mp_sma.start()
oscillation_got_detected=False
oscillation_last_seen=0.0
while (not q_sma.empty()):
meter=q_sma.get()
# populate ringbuffer for SMA meter
oscillation_got_detected,meter_ringbuffer_W=populate_sma_ringbuffer(meter,meter_ringbuffer_W)
print_debug.my_debug(str(meter_ringbuffer_W.get()),"meter_ringbuffer")
# query SEMS
###############
if (Sems_Flag):
# query sems -portal
#####################
sems_join=False
if (now - last_sems_run > 15):
sems_join=True
last_sems_run=now
mp_do_auth_and_query = multiprocessing.Process(target=sems.do_auth_and_query,args=(token,uid,timestamp,expiry,api,sems_url_oauth,q_do_auth_and_query))
mp_do_auth_and_query.start()
while (not q_do_auth_and_query.empty()):
q=q_do_auth_and_query.get()
token=q[0]
uid=q[1]
timestamp=q[2]
expiry=q[3]
api=q[4]
bp_a=q[5]
bp_w=q[6]
sems_success=q[7]
sems_soc=q[8]
#print("sems_success",sems_success)
if (sems_success):
print_debug.my_debug("sems_query", "Success")
print_debug.my_debug ("sems ampere[A] (+ charge, -discharge)",bp_a)
print_debug.my_debug ("sems power[W] (+ charge, -discharge)",bp_w)
print_debug.my_debug("sems soc[%]",sems_soc)
sems_current_ringbuffer_A.append(bp_a)
if (global_mqtt):
my_mqtt.publish(mqtt_client,"sems/Ampere",str(bp_a))
my_mqtt.publish(mqtt_client,"sems/Watt",str(bp_w))
my_mqtt.publish(mqtt_client,"sems/soc",str(sems_soc))
else:
print_debug.my_debug("sems_query", "Failure")
print_debug.my_debug("sems ringbuffer[A]",sems_current_ringbuffer_A.get())
print_debug.my_debug("sems average[A]",sems_current_ringbuffer_A.average())
print_debug.my_debug("sems min[A]",sems_current_ringbuffer_A.min())
print_debug.my_debug("sems max[A]",sems_current_ringbuffer_A.max())
print("sems done")
###########################
# query SEMS via HMC5883l
###########################
if (Sems_Flag and hmc_success):
hmc_read_x= my_hmc5883l.read_raw_data(my_hmc5883l.X_MSB,i2c_bus)
hmc_read_y= my_hmc5883l.read_raw_data(my_hmc5883l.Y_MSB,i2c_bus)
hmc_read_z= my_hmc5883l.read_raw_data(my_hmc5883l.Z_MSB,i2c_bus)
if (hmc_read_y > -300):
if (hmc_read_z > 0):
hmc_ampere=48
else:
hmc_ampere=-48
else:
hmc_ampere=40/669*hmc_read_y+40
hmc_ringbuffer_A.append(round(hmc_ampere,2))
print_debug.my_debug("hmc_x",hmc_read_x)
print_debug.my_debug("hmc_y",hmc_read_y)
print_debug.my_debug("hmc_z",hmc_read_z)
print_debug.my_debug("hmc_ampere",hmc_ampere)
print_debug.my_debug("hmc_ringbuffer[A]",hmc_ringbuffer_A.get())
print_debug.my_debug("hmc_average_ringbuffer[A]",hmc_ringbuffer_A.average())
print("hmc done")
#############################
# Setting the discharge limit
#############################
# undervolt protection
#####################
Not_to_exceed_discharge_limit=set_discharge_limit(min_volt,Not_to_exceed_discharge_limit,my_soc)
if (Sems_Flag):
if (not use_hmc):
if (sems_current_ringbuffer_A.average()> 400/50): # we allow it to charge for approx 400W
# goodwe charges, then solis must not discharge
l=-1* current_ringbuffer.average() # assuming we discharge, lets make a postiv value
l=l-bp_a # subtract goodwe ampaere
if (l>0 and meter_ringbuffer_W.average() > -40): #only reduce if resulting limit >0 and if average > -20
# e.g. it does not make sense to lower doscharge, if we are at -1000W
Battery_discharge_current_limit=(int)(l)
else:
Battery_discharge_current_limit=0
goodwe_enforced_zero_discharge=True
else:
goodwe_enforced_zero_discharge=False
# using HMC
else:
if(hmc_ringbuffer_A.average() > 2):
goodwe_enforced_zero_discharge=True
if Battery_discharge_current_limit >=1:
Battery_discharge_current_limit=Battery_discharge_current_limit-1
else:
goodwe_enforced_zero_discharge=False
if Battery_discharge_current_limit < Not_to_exceed_discharge_limit:
Battery_discharge_current_limit=Battery_discharge_current_limit+1
print_debug.my_debug("goodwe_enforced_zero_discharge",goodwe_enforced_zero_discharge)
# discharge-limit slow increase back again
###########################################
if (now-timestamp_generic_interval_5> generic_interval_5 and not goodwe_enforced_zero_discharge):
if (Battery_discharge_current_limit<Not_to_exceed_discharge_limit):
Battery_discharge_current_limit=Battery_discharge_current_limit+2
print_debug.my_debug("slow discharge increase","2")
if (Battery_discharge_current_limit>Not_to_exceed_discharge_limit):
Battery_discharge_current_limit=Not_to_exceed_discharge_limit
print_debug.my_debug("failsafe - limit discharge_limit", Not_to_exceed_discharge_limit)
# discharge-limit fast increase back again
###########################################
#if (meter_ringbuffer_W.average() < -700 and not goodwe_enforced_zero_discharge):
if (meter_ringbuffer_W.average() < -700):
Battery_discharge_current_limit=Not_to_exceed_discharge_limit
print_debug.my_debug("failsafe - limit discharge_limit",Not_to_exceed_discharge_limit)
print_debug.my_debug("Battery_charge_current_limit_before_charge_limit", Battery_charge_current_limit)
#############################
# Setting the charge limit
#############################
# overvolt protection - set Battery_charge_current_limit_set_by_overvolt_protect
#####################
# first deriving the MAXIMUM of charge-limit: Battery_charge_current_limit_set_by_overvolt_protect
# used as a safeguard - whatever below stuff does, it must not be larger then the max Battery_charge_current_limit_set_by_overvolt_protect
Battery_charge_current_limit_set_by_overvolt_protect, timestamp_charge_limit_change_overvolt_protect= \
set_charge_limit_by_max_monomer(max_volt,Battery_charge_current_limit_set_by_overvolt_protect,my_soc,oscillation_got_detected,timestamp_charge_limit_change_overvolt_protect)
print_debug.my_debug("result Battery_charge_current_limit_set_by_overvolt_protect,set_charge_limit",
Battery_charge_current_limit_set_by_overvolt_protect)
# CHARGING: enable/ disable charging based on goodwe
#######################################
if (Sems_Flag):
sma_ringbuffer_limit=100
hmc_ringbuffer_A_limit=10
sma_meter_limit1 = 2000
sma_meter_limit2 = 4000
# why: if meter_ringbuffer_W.average()< 1000: >> if ringbuffer >1000, e.g. 3kw then there is no need to set charge-limit to zero
# why -1 for: sems_current_ringbuffer_A.average()<-1 >>> sems sometimes disharges with -40W, but even then we want the solis allow to charge..
# that why we set 1A - only if goodwe discharges > 50W (1A * 50V), then we want to stop charging the solis
print("before if")
if (use_hmc):
# hmc_allow charging
if ((hmc_ringbuffer_A.average()>hmc_ringbuffer_A_limit and hmc_ringbuffer_A.latest()>hmc_ringbuffer_A_limit) or (meter_ringbuffer_W.average()>sma_ringbuffer_limit)):
#goodwe charging with over 20A - so it should be safe to allow charging solis as well
# or sma_ringbuffer has heftover watts
goodwe_enforced_zero_charge=False
# increase back again if prevois set to 0
print_debug.my_debug ("hmc_allow_charge","xxxxx1")
if (now-timestamp_generic_interval_5> generic_interval_5) and (Battery_charge_current_limit<Battery_charge_current_limit_set_by_overvolt_protect):
try:
fast_offset = (int) ((meter_ringbuffer_W.average() / my_volt)+0)
except:
fast_offset = 0.0
slow_offset=1
print_debug.my_debug ("hmc_allow_charge","xxxxx20")
if (not meter_ringbuffer_W.is_empty() and meter_ringbuffer_W.latest() > sma_meter_limit2):
Battery_charge_current_limit=Battery_charge_current_limit_set_by_overvolt_protect
print_debug.my_debug ("hmc_allow_charge","xxxxx21")
elif (not meter_ringbuffer_W.is_empty() and meter_ringbuffer_W.latest() > sma_meter_limit1):
Battery_charge_current_limit=Battery_charge_current_limit + 10
print_debug.my_debug ("hmc_allow_charge","xxxxx22")
elif (meter_ringbuffer_W.average()>4000):
Battery_charge_current_limit=Battery_charge_current_limit_set_by_overvolt_protect
print_debug.my_debug ("hmc_allow_charge","xxxxx30")
elif (meter_ringbuffer_W.average()>2000):
Battery_charge_current_limit=Battery_charge_current_limit+slow_offset+fast_offset
print_debug.my_debug ("hmc_allow_charge","xxxxx40")
else:
Battery_charge_current_limit=Battery_charge_current_limit+slow_offset
print_debug.my_debug ("hmc_allow_charge","xxxxx50")
print_debug.my_debug("charge limit slow increase",Battery_charge_current_limit)
#### all of the below
######################
#### meter_ringbuffer_W.average is SMALLER then sma_ringbuffer_limit
#### and
#### hmc_ringbuffer_A.average is smaller then hmc_ringbuffer_A_limit
# hmc_disallow charging when goodwe discharges
# < -12
elif (hmc_ringbuffer_A.average()<=-12):
#Battery_charge_current_limit=math.floor(Battery_charge_current_limit*3/8)
Battery_charge_current_limit=Battery_charge_current_limit-2
print_debug.my_debug("zz trigger charge limit 0, goodwe discharging","True")
goodwe_enforced_zero_charge=True
print_debug.my_debug ("hmc_allow_charge","xxxxx80")
# < -4
elif (hmc_ringbuffer_A.average()<=-4):
#Battery_charge_current_limit=0
Battery_charge_current_limit=Battery_charge_current_limit-1
#Battery_charge_current_limit=math.floor(Battery_charge_current_limit*6/8)
print_debug.my_debug("zz trigger charge limit 0, goodwe discharging","True")
goodwe_enforced_zero_charge=True
print_debug.my_debug ("hmc_allow_charge","xxxxx70")
# < 16 , latest <10
# lower solis charging in case goodwe goes really low
elif (hmc_ringbuffer_A.average()<=hmc_ringbuffer_A_limit and hmc_ringbuffer_A.latest()<10):
#start lowering charge-limit
Battery_charge_current_limit=Battery_charge_current_limit-1
print_debug.my_debug ("hmc_allow_charge","xxxxx60")
# < 16
# do nothing in case goodwe charges below 20A
elif (hmc_ringbuffer_A.average()<=hmc_ringbuffer_A_limit):
#do not change charge-limit
Battery_charge_current_limit=Battery_charge_current_limit
print_debug.my_debug ("hmc_allow_charge","xxxxx64")
# < 16
# do nothing in case goodwe charges below 20A
elif (hmc_ringbuffer_A.average()>hmc_ringbuffer_A_limit):
#do not change charge-limit
Battery_charge_current_limit=Battery_charge_current_limit
print_debug.my_debug ("hmc_allow_charge","xxxxx65")
#safekeeping, this else case should never be reached
#hmc_disallow charging
else:
Battery_charge_current_limit=0
print_debug.my_debug ("hmc_allow_charge","xxxxx90")
print_debug.my_debug("xx60 trigger charge limit 0, goodwe discharging","True")
goodwe_enforced_zero_charge=True
# do not use hmc
else:
# disallow charging
if ( meter_ringbuffer_W.average()< sma_ringbuffer_limit):
if (sems_current_ringbuffer_A.average()<=-1.2): # starting at -1 Ampere. in theory it shll be zero
# goodwe/sems is discharging
# if goodwe discharges, then we shall not charge the solis
Battery_charge_current_limit=0
print_debug.my_debug("yy trigger charge limit 0, goodwe discharging","True")
goodwe_enforced_zero_charge=True
timestamp_sems_triggered_reduce_charge_limit=now
else:
goodwe_enforced_zero_charge=False
# average > limit, so we shall allow charging
else:
# avergage >limit, so enough power leftover
goodwe_enforced_zero_charge=False
if (now-timestamp_generic_interval_5> generic_interval_5):
# if average > limit, then we have enough power left over. so we shall allowing to charge
try:
offset = (int) ((meter_ringbuffer_W.average() / my_volt)+0)
except:
offset = 0.0
Battery_charge_current_limit=Battery_charge_current_limit+offset
print_debug.my_debug("charge limit slow increase",Battery_charge_current_limit)
# safeguard - never go beynd overvolt protect limit
if (Battery_charge_current_limit>Battery_charge_current_limit_set_by_overvolt_protect):
Battery_charge_current_limit = Battery_charge_current_limit_set_by_overvolt_protect
print_debug.my_debug("Battery_charge_current_limit_before_osicllation_detection", Battery_charge_current_limit)
print_debug.my_debug("goodwe_enforced_zero_charge", goodwe_enforced_zero_charge)
print("before oscillation detection")
# oscillation detection
#######################
#if (oscillation_enabled_flag):
if (True):
# oscillation detection - requires SMA enery meter
if (oscillation_got_detected):
print_debug.my_debug("oscillation_got_detected", "True")
print("oscillation_got_detected", "True")
oscillation_last_seen=now
else:
print_debug.my_debug("oscillation_got_detected", "False")
if (now - oscillation_mqtt_last_run > oscillation_mqtt_interval):
oscillation_mqtt_last_run=now
if oscillation_got_detected:
if (global_mqtt):
my_mqtt.publish(mqtt_client,"sems/oscillation_detected",1)
else:
if (global_mqtt):
my_mqtt.publish(mqtt_client,"sems/oscillation_detected",0)
if (oscillation_enabled_flag):
# modification allowed after interval
if(now - timestamp_last_osci_limit_change_run > 60):
timestamp_last_osci_limit_change_run = now
#reduce the limits
if (oscillation_got_detected):
Battery_charge_current_limit=(int)(Battery_charge_current_limit/3)
Battery_discharge_current_limit=(int)(Battery_discharge_current_limit/3)
print_debug.my_debug("discharge-limit-reduced because of oscillation",Battery_discharge_current_limit)
print_debug.my_debug("charge-limit-reduced because of oscillation",Battery_charge_current_limit)
print_debug.my_debug("XX2 Battery_charge_current_limit_set_by_overvolt_protect",Battery_charge_current_limit_set_by_overvolt_protect)
print_debug.my_debug("XX2 Battery_discharge_current_limit after oscillation",Battery_discharge_current_limit)
print_debug.my_debug("XX2 Battery_charge_current_limit after oscillation",Battery_charge_current_limit)
#if (allow_larger_100_percent_soc and not goodwe_enforced_zero_charge):
# Battery_charge_current_limit = Battery_charge_current_limit_set_by_overvolt_protect
# quick oscilaation hack - fix load to a max
#if Battery_charge_current_limit > 41:
# Battery_charge_current_limit = 20
#if Battery_discharge_current_limit > 41:
# Battery_discharge_current_limit = 20
# DEBUG ONLY - overwirtes any previus automtism derived values
#Battery_charge_current_limit=40
#Battery_discharge_current_limit=60
############
# safeguard : no further charge/discharge limit changes allowed after here!
############
# Safeguard - the not_to_exceeds values are the cell-protection values.
# having smaller limits is ok, but never having larger values
if (Battery_charge_current_limit>Battery_charge_current_limit_set_by_overvolt_protect):
Battery_charge_current_limit=Battery_charge_current_limit_set_by_overvolt_protect
print_debug.my_debug("Safeguard max charge Limit kicked in","True")
print("Safeguard max charge Limit kicked in","True")
elif Battery_charge_current_limit <0:
Battery_charge_current_limit=0
print_debug.my_debug("Safeguard negative charge Limit kicked in","True")
print("Safeguard negative charge Limit kicked in","True")
if (Battery_discharge_current_limit>Not_to_exceed_discharge_limit):
Battery_discharge_current_limit=Not_to_exceed_discharge_limit
print_debug.my_debug("Safeguard discharge Limit kicked in","True")
print("Safeguard discharge Limit kicked in","True")
if (not bms_read_success):
Battery_discharge_current_limit=0
Battery_charge_current_limit=0
print("if_not_bms_read_success, BMS reading FAILED",Battery_discharge_current_limit)
print_debug.my_debug("safeguard_reduced_discharge to zero","BMS-Reading-failed")
print("after safeguard")
# update data for can-bus
#########################
msg_tx_Network_alive_msg.data = db.encode_message('Network_alive_msg',{'Alive_packet': Alive_packet})
task_tx_Network_alive_msg.modify_data(msg_tx_Network_alive_msg) # failure, produces error message
msg_tx_Battery_SoC_SoH.data = db.encode_message('Battery_SoC_SoH',{'SoC': my_soc,'SoH': 100})
task_tx_Battery_SoC_SoH.modify_data(msg_tx_Battery_SoC_SoH)
print_debug.my_debug ("SOC sent via canbus", my_soc)
msg_tx_Battery_actual_values_UIt.data = db.encode_message('Battery_actual_values_UIt',{
'Battery_temperature' : my_temp,
'Battery_current' : my_ampere,
'Battery_voltage' : my_volt})
task_tx_Battery_actual_values_UIt.modify_data(msg_tx_Battery_actual_values_UIt)
msg_tx_Battery_limits.data = db.encode_message('Battery_limits',{
'Battery_discharge_current_limit' : Battery_discharge_current_limit,
'Battery_charge_current_limit' : Battery_charge_current_limit,
'Battery_charge_voltage' : Battery_charge_voltage_default,
'Battery_discharge_voltage' : Battery_discharge_voltage_default })
task_tx_Battery_limits.modify_data (msg_tx_Battery_limits)
print_debug.my_debug ("CANBUS: Battery_charge_current_limit", Battery_charge_current_limit)
print_debug.my_debug ("CANBUS: Battery_discharge_current_limit", Battery_discharge_current_limit)
# sending some MQTT
print_debug.my_debug("next mqtt sent in seconds",int(mqtt_sent_interval - (now - last_mqtt_run)))
if (now - mqtt_sent_interval > last_mqtt_run ): #wait 20seconds before publish next mqtt
last_mqtt_run=now
if (global_mqtt):
topic="jk_pylon/Battery_charge_current_limit"
message=str(Battery_charge_current_limit)
my_mqtt.publish(mqtt_client,topic,message)
topic="jk_pylon/Battery_discharge_current_limit"
message=str(Battery_discharge_current_limit)
my_mqtt.publish(mqtt_client,topic,message)
topic="jk_pylon/HMC_Sems_Average_A"
message=str(hmc_ringbuffer_A.average())
my_mqtt.publish(mqtt_client,topic,message)
topic="jk_pylon/SMA_Average_W"
message=str(meter_ringbuffer_W.average())
my_mqtt.publish(mqtt_client,topic,message)
print("mqtt_done")
# compress logfiles
if (write_to_file and (now-timestamp_generic_interval_5> generic_interval_5)):
print_debug.my_compress(filename)
print("after_compress")
# end of main loop
if (now-timestamp_generic_interval_5> generic_interval_5):
timestamp_generic_interval_5=now
# sending all the joins
#if (check_can_join):
# mp_check_can.join()
if (read_bms_join):
mp_read_bms.join()
print("join_x1")
mp_sma.join()
print("join_x2")
if (Sems_Flag):
if (sems_join):
mp_do_auth_and_query.join()
# check all the mp-queues - shall never increase
print("print_routine")
print("BMS status ", bms_read_success, " run ", "{:5d}".format(Alive_packet))
print("q_check_can:", "{:04d}".format(q_check_can.qsize())," q_my_read_bms:", "{:04d}".format(q_my_read_bms.qsize())," q_do_auth_and_query:", "{:04d}".format(q_do_auth_and_query.qsize()), " q_sma: ", "{:04d}".format(q_sma.qsize()))
print ("Ampere: ", "{:04.1f}".format(my_ampere), " Volt: ", "{:04.1f}".format(my_volt), " min_volt: ","{:1.2f}".format(min_volt)," max_volt: ","{:1.2f}".format(max_volt))
print ("charge_lim: ", "{:02d}".format(Battery_charge_current_limit), " discharge_l: ", "{:02d}".format(Battery_discharge_current_limit)," sent_soc% ","{:3d}".format(my_soc))
print ("hmc_5883y: ", "{:03d}".format(hmc_read_y), " hmc_ampere ","{:04.1f}".format(hmc_ampere))
time.sleep(sleepTime)
print("timeLsleep_done")
task.stop()
if __name__ == "__main__":
# file logging
##############
if (write_to_file):
#my_file=open(filename,'w')
print ("Logging to file:",filename)
print_debug.log_setup(filename)
if (not log_to_console):
print("logging to console is disabled")
print(" -enable logging to console by setting variable log_to_console=True")
# JK BMS UART INIT
##################
usb_jk="/dev/ttyUSB0"
bms = serial.Serial()
bms.port=usb_jk
bms.baudrate = 115200
bms.timeout = 0.2
try:
bms.open()
except:
s1="FATAL ERROR: BMS not found - correct ttyUSB choosen?. see file: "
s1=s1+sys.argv[0]
s2="check for variable usb_jk. Aborting/exiting the program"
print(s1,s2)
print_debug.my_debug(s1,s2)
sys.exit()
print (datetime.datetime.now().strftime("%Y-%m-%d %H:%M"))
#my_now = datetime.now()
#dt_string = my_now.strftime("%d/%m/%Y %H:%M:%S")
#print("date and time =", dt_string)
# CAN BUS INIT
##############
#TO debug with no CAN physical interface use
#sudo ip link add dev vcan0 type vcan
#sudo ip link set up vcan0
db = cantools.db.load_file(can_db)
#db = cantools.db.load_file(/home/behn/jk_pylon/pylon_CAN_210124.dbc)
msg_data_Network_alive_msg = {
'Alive_packet': 0}
msg_data_Battery_SoC_SoH = {
'SoC': 80,
'SoH': 100}
msg_data_Battery_Request = {
'Full_charge_req' : 0,
'Force_charge_req_II' : 0,
'Force_charge_req_I' : 0,
'Discharge_enable' : 1,
'Charge_enable' : 1}
msg_data_Battery_actual_values_UIt = {
'Battery_temperature' : 20,
'Battery_current' : 0,