- Buggy, not recomended without good knowlage of matlab
- Matlab
- Simscape
- elec_inductor_hysteresis Model
This tool is very user unfriendly
sp = 1; % starting index for logging
init parameters in order
% dBdH0 % Anhysteretic B-H gradient when H is zero
% B1 % Flux density point on anhysteretic B-H curve
% H1 % Corresponding field strength
% c % Coefficient for reversible magnetization, c
% K % Bulk coupling coefficient, K
% alpha % Inter-domain coupling factor
% error %
This here is a good fit for AlNiCo 5
a(1,:)= [4.76258753832144e-05 1.08137459383704 31510.3190144165 0.125292584870499 83177.9056903517 0.0622798260003811 11.9530626244814];
Run
- This does like to get stuck at local minimas sometimes
- Extract reference BH loops using grabit.m
- It can take a long time to find a good fit if your initial parameters are too far of
TODO