Related Issues
transformers==4.48.0
(Breaking change in v4.48.0 and Python 3.9 huggingface/transformers#35639)AttributeError: 'ORTModelForFeatureExtraction' object has no attribute 'input_names'. Did you mean: 'inputs_names'
. I cannot reproduce it locally but only in the CI.transformers
causes strange dependency resolution. I also think we don't need that specific pin: it is already pinned by Optimum - see https://github.com/huggingface/optimum/blob/0a2b843ed4da48002e36d529fee5b1c607d6f301/setup.py#L51Proposed Changes:
transformers
and letoptimum
handle the dependencyHow did you test it?