32 changes: 32 additions & 0 deletions ebusd-2.1.x/de/vaillant/08.recov.csv
Original file line number Diff line number Diff line change
@@ -0,0 +1,32 @@
# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment
#,recov,recoVair 260,,,,,,,,,,,
# ##### Generell #####,,,,,,,,,,,,,
*r,,,,,,B513,,,,IGN:2,,,
*w,,,,,,B509,,,,,,,
r2,recov,VentIntensityDay,Lueftungsintensitaet Tag auslesen,,,,048a03,,,UCH,,,
r2,recov,VentIntensityNight,Lueftungsintensitaet Nacht auslesen,,,,048b03,,,UCH,,,
r2,recov,VentHeatRecovery,Waermerueckgewinnung auslesen,,,,048c03,,,UCH,0=auto;1=an;2=aus,,
w,recov,SetVentIntensity1,Lueftungsintensitaet 1 setzen,,,,0e8a0301,,,,,,
w,recov,SetVentIntensity2,Lueftungsintensitaet 2 setzen,,,,0e8a0302,,,,,,
w,recov,SetVentIntensity3,Lueftungsintensitaet 3 setzen,,,,0e8a0303,,,,,,
w,recov,SetVentIntensity4,Lueftungsintensitaet 4 setzen,,,,0e8a0304,,,,,,
w,recov,SetVentIntensity5,Lueftungsintensitaet 5 setzen,,,,0e8a0305,,,,,,
w,recov,SetVentIntensity6,Lueftungsintensitaet 6 setzen,,,,0e8a0306,,,,,,
w,recov,SetVentHeatRecoveryAuto,Waermerueckgewinnung Auto,,,,0e8c0300,,,,,,
w,recov,SetVentHeatRecoveryOn,Waermerueckgewinnung anschalten,,,,0e8c0301,,,,,,
w,recov,SetVentHeatRecoveryOff,Waermerueckgewinnung ausschalten,,,,0e8c0302,,,,,,
w,recov,SetVentDay,Lueftung Tag setzen,,,B522,000200FFFF,,,,,,
w,recov,SetVentNight,Lueftung Nacht setzen,,,B522,000100FFFF,,,,,,
w,recov,SetVentBoost,Stosslueften aktivieren,,,B522,000300FFFF,,,,,,
# ##### Weitere #####,,,,,,,,,,,,,
*r,,,,,,B509,,,,IGN:2,,,
*w,,,,,,B509,,,,,,,
r9,recov,BypassPosition,Position der Bypass-Klappe,,,,290b0e,,,UIN,10,,
r,recov,TempOutsideAir,Temperatur Aussenluft,,,,290c0e,,,tempsensor,,,
r,recov,TempOutgoingAir,Temperatur Fortluft,,,,290d0e,,,tempsensor,,,
r,recov,TempWasteAir,Temperatur Abluft,,,,29b40d,,,tempsensor,,,
r,recov,TempInletAir,Temperatur Zuluft,,,,29b30d,,,tempsensor,,,
r2,recov,HumiWasteAir,Luftfeuchtigkeit Zuluft,,,,298503,,,percent,,,
r9,recov,FrostProtection,Frostschutzelement aktiv,,,,29f10c,,,onoff,,,
r,recov,PreferredTemp,Wunschtemperatur,,,,29140e,,,temp,,,
r2,recov,FlowActual,aktueller Volumenstrom,,,,29030e,,,UIN,,m3/h,
32 changes: 32 additions & 0 deletions ebusd-2.1.x/en/vaillant/08.recov.csv
Original file line number Diff line number Diff line change
@@ -0,0 +1,32 @@
# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment
#,recov,recoVair 260,,,,,,,,,,,
# ##### Generell #####,,,,,,,,,,,,,
*r,,,,,,B513,,,,IGN:2,,,
*w,,,,,,B509,,,,,,,
r2,recov,VentIntensityDay,Read Ventilation Intensity Day,,,,048a03,,,UCH,,,
r2,recov,VentIntensityNight,Read Ventilation Intensity Night,,,,048b03,,,UCH,,,
r2,recov,VentHeatRecovery,Read Heat Recovery,,,,048c03,,,UCH,0=auto;1=on;2=off,,
w,recov,SetVentIntensity1,Set Ventilation Intensity 1,,,,0e8a0301,,,,,,
w,recov,SetVentIntensity2,Set Ventilation Intensity 2,,,,0e8a0302,,,,,,
w,recov,SetVentIntensity3,Set Ventilation Intensity 3,,,,0e8a0303,,,,,,
w,recov,SetVentIntensity4,Set Ventilation Intensity 4,,,,0e8a0304,,,,,,
w,recov,SetVentIntensity5,Set Ventilation Intensity 5,,,,0e8a0305,,,,,,
w,recov,SetVentIntensity6,Set Ventilation Intensity 6,,,,0e8a0306,,,,,,
w,recov,SetVentHeatRecoveryAuto,Set Heat Recovery Auto,,,,0e8c0300,,,,,,
w,recov,SetVentHeatRecoveryOn,Turn On Heat Recovery,,,,0e8c0301,,,,,,
w,recov,SetVentHeatRecoveryOff,Turn Off Heat Recovery,,,,0e8c0302,,,,,,
w,recov,SetVentDay,Set Ventilation Day,,,B522,000200FFFF,,,,,,
w,recov,SetVentNight,Set Ventilation Night,,,B522,000100FFFF,,,,,,
w,recov,SetVentBoost,Activate Boost Ventilation,,,B522,000300FFFF,,,,,,
# ##### Weitere #####,,,,,,,,,,,,,
*r,,,,,,B509,,,,IGN:2,,,
*w,,,,,,B509,,,,,,,
r9,recov,BypassPosition,Position of Bypass Flap,,,,290b0e,,,UIN,10,,
r,recov,TempOutsideAir,Outside Air Temperature,,,,290c0e,,,tempsensor,,,
r,recov,TempOutgoingAir,Outgoing Air Temperature,,,,290d0e,,,tempsensor,,,
r,recov,TempWasteAir,Waste Air Temperature,,,,29b40d,,,tempsensor,,,
r,recov,TempInletAir,Inlet Air Temperature,,,,29b30d,,,tempsensor,,,
r2,recov,HumiWasteAir,Relative Humidity Waste Air,,,,298503,,,percent,,,
r9,recov,FrostProtection,Frost Protection Element Active,,,,29f10c,,,onoff,,,
r,recov,PreferredTemp,Desired Temperature,,,,29140e,,,temp,,,
r2,recov,FlowActual,Current Volume Flow,,,,29030e,,,UIN,,m3/h,