Notifications
You must be signed in to change notification settings - Fork 52
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Migrate to ACLINT #66
Merged
Merged
Changes from all commits
Commits
Show all changes
2 commits
Select commit
Hold shift + click to select a range
File filter
Filter by extension
Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
|
@@ -53,7 +53,7 @@ OBJS := \ | |
plic.o \ | ||
uart.o \ | ||
main.o \ | ||
clint.o \ | ||
aclint.o \ | ||
$(OBJS_EXTRA) | ||
|
||
deps := $(OBJS:%.o=.%.o.d) | ||
|
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,218 @@ | ||
#include <stdint.h> | ||
#include "device.h" | ||
#include "riscv.h" | ||
#include "riscv_private.h" | ||
|
||
/* ACLINT MTIMER */ | ||
void aclint_mtimer_update_interrupts(hart_t *hart, mtimer_state_t *mtimer) | ||
{ | ||
if (semu_timer_get(&mtimer->mtime) >= mtimer->mtimecmp[hart->mhartid]) | ||
hart->sip |= RV_INT_STI_BIT; /* Set Supervisor Timer Interrupt */ | ||
else | ||
hart->sip &= ~RV_INT_STI_BIT; /* Clear Supervisor Timer Interrupt */ | ||
} | ||
|
||
static bool aclint_mtimer_reg_read(mtimer_state_t *mtimer, | ||
uint32_t addr, | ||
uint32_t *value) | ||
{ | ||
/* 'addr & 0x4' is used to determine the upper or lower 32 bits | ||
* of the mtimecmp register. If 'addr & 0x4' is 0, then the lower 32 | ||
* bits are accessed. | ||
* | ||
* 'addr >> 3' is used to get the index of the mtimecmp array. In | ||
* "ACLINT MTIMER Compare Register Map", each mtimecmp register is 8 | ||
* bytes long. So, we need to divide the address by 8 to get the index. | ||
*/ | ||
|
||
/* mtimecmp (0x4300000 ~ 0x4307FF8) */ | ||
if (addr < 0x7FF8) { | ||
*value = | ||
(uint32_t) (mtimer->mtimecmp[addr >> 3] >> (addr & 0x4 ? 32 : 0)); | ||
return true; | ||
} | ||
|
||
/* mtime (0x4307FF8 ~ 0x4308000) */ | ||
if (addr < 0x8000) { | ||
*value = (uint32_t) (semu_timer_get(&mtimer->mtime) >> | ||
(addr & 0x4 ? 32 : 0)); | ||
return true; | ||
} | ||
return false; | ||
} | ||
|
||
static bool aclint_mtimer_reg_write(mtimer_state_t *mtimer, | ||
uint32_t addr, | ||
uint32_t value) | ||
{ | ||
/* The 'cmp_val & 0xFFFFFFFF' is used to select the upper 32 bits | ||
* of mtimer->mtimecmp[addr >> 3], then shift the value to the left by | ||
* 32 bits to set the upper 32 bits. | ||
* | ||
* Similarly, 'cmp_val & 0xFFFFFFFF00000000ULL' is used to select the lower | ||
* 32 bits of mtimer->mtimecmp[addr >> 3]. | ||
*/ | ||
|
||
/* mtimecmp (0x4300000 ~ 0x4307FF8) */ | ||
if (addr < 0x7FF8) { | ||
uint64_t cmp_val = mtimer->mtimecmp[addr >> 3]; | ||
|
||
if (addr & 0x4) | ||
cmp_val = (cmp_val & 0xFFFFFFFF) | ((uint64_t) value << 32); | ||
else | ||
cmp_val = (cmp_val & 0xFFFFFFFF00000000ULL) | value; | ||
|
||
mtimer->mtimecmp[addr >> 3] = cmp_val; | ||
return true; | ||
} | ||
|
||
/* mtime (0x4307FF8 ~ 0x4308000) */ | ||
if (addr < 0x8000) { | ||
uint64_t mtime_val = mtimer->mtime.begin; | ||
if (addr & 0x4) | ||
mtime_val = (mtime_val & 0xFFFFFFFF) | ((uint64_t) value << 32); | ||
else | ||
mtime_val = (mtime_val & 0xFFFFFFFF00000000ULL) | value; | ||
|
||
semu_timer_rebase(&mtimer->mtime, mtime_val); | ||
return true; | ||
} | ||
|
||
return false; | ||
} | ||
|
||
void aclint_mtimer_read(hart_t *hart, | ||
mtimer_state_t *mtimer, | ||
uint32_t addr, | ||
uint8_t width, | ||
uint32_t *value) | ||
{ | ||
if (!aclint_mtimer_reg_read(mtimer, addr, value)) | ||
vm_set_exception(hart, RV_EXC_LOAD_FAULT, hart->exc_val); | ||
|
||
*value >>= RV_MEM_SW - width; | ||
} | ||
|
||
void aclint_mtimer_write(hart_t *hart, | ||
mtimer_state_t *mtimer, | ||
uint32_t addr, | ||
uint8_t width, | ||
uint32_t value) | ||
{ | ||
if (!aclint_mtimer_reg_write(mtimer, addr, value << (RV_MEM_SW - width))) | ||
vm_set_exception(hart, RV_EXC_STORE_FAULT, hart->exc_val); | ||
} | ||
|
||
/* ACLINT MSWI */ | ||
void aclint_mswi_update_interrupts(hart_t *hart, mswi_state_t *mswi) | ||
{ | ||
if (mswi->msip[hart->mhartid]) | ||
hart->sip |= RV_INT_SSI_BIT; /* Set Machine Software Interrupt */ | ||
else | ||
hart->sip &= ~RV_INT_SSI_BIT; /* Clear Machine Software Interrupt */ | ||
} | ||
|
||
static bool aclint_mswi_reg_read(mswi_state_t *mswi, | ||
uint32_t addr, | ||
uint32_t *value) | ||
{ | ||
/* 'msip' is an array where each entry corresponds to a Hart, | ||
* each entry is 4 bytes (32 bits). So, we need to divide the address | ||
* by 4 to get the index. | ||
*/ | ||
|
||
/* Address range for msip: 0x4400000 ~ 0x4404000 */ | ||
if (addr < 0x4000) { | ||
*value = mswi->msip[addr >> 2]; | ||
return true; | ||
} | ||
return false; | ||
} | ||
|
||
static bool aclint_mswi_reg_write(mswi_state_t *mswi, | ||
uint32_t addr, | ||
uint32_t value) | ||
{ | ||
if (addr < 0x4000) { | ||
mswi->msip[addr >> 2] = value & 0x1; /* Only the LSB is valid */ | ||
return true; | ||
} | ||
return false; | ||
} | ||
|
||
void aclint_mswi_read(hart_t *hart, | ||
mswi_state_t *mswi, | ||
uint32_t addr, | ||
uint8_t width, | ||
uint32_t *value) | ||
{ | ||
if (!aclint_mswi_reg_read(mswi, addr, value)) | ||
vm_set_exception(hart, RV_EXC_LOAD_FAULT, hart->exc_val); | ||
|
||
*value >>= RV_MEM_SW - width; | ||
} | ||
|
||
void aclint_mswi_write(hart_t *hart, | ||
mswi_state_t *mswi, | ||
uint32_t addr, | ||
uint8_t width, | ||
uint32_t value) | ||
{ | ||
if (!aclint_mswi_reg_write(mswi, addr, value << (RV_MEM_SW - width))) | ||
vm_set_exception(hart, RV_EXC_STORE_FAULT, hart->exc_val); | ||
} | ||
|
||
/* ACLINT SSWI */ | ||
void aclint_sswi_update_interrupts(hart_t *hart, sswi_state_t *sswi) | ||
{ | ||
if (sswi->ssip[hart->mhartid]) | ||
hart->sip |= RV_INT_SSI_BIT; /* Set Supervisor Software Interrupt */ | ||
else | ||
hart->sip &= ~RV_INT_SSI_BIT; /* Clear Supervisor Software Interrupt */ | ||
} | ||
|
||
static bool aclint_sswi_reg_read(__attribute__((unused)) sswi_state_t *sswi, | ||
uint32_t addr, | ||
uint32_t *value) | ||
{ | ||
/* Address range for ssip: 0x4500000 ~ 0x4504000 */ | ||
if (addr < 0x4000) { | ||
*value = 0; /* Upper 31 bits are zero, and LSB reads as 0 */ | ||
return true; | ||
} | ||
return false; | ||
} | ||
|
||
static bool aclint_sswi_reg_write(sswi_state_t *sswi, | ||
uint32_t addr, | ||
uint32_t value) | ||
{ | ||
if (addr < 0x4000) { | ||
sswi->ssip[addr >> 2] = value & 0x1; /* Only the LSB is valid */ | ||
|
||
return true; | ||
} | ||
return false; | ||
} | ||
|
||
void aclint_sswi_read(hart_t *hart, | ||
sswi_state_t *sswi, | ||
uint32_t addr, | ||
uint8_t width, | ||
uint32_t *value) | ||
{ | ||
if (!aclint_sswi_reg_read(sswi, addr, value)) | ||
vm_set_exception(hart, RV_EXC_LOAD_FAULT, hart->exc_val); | ||
|
||
*value >>= RV_MEM_SW - width; | ||
} | ||
|
||
void aclint_sswi_write(hart_t *hart, | ||
sswi_state_t *sswi, | ||
uint32_t addr, | ||
uint8_t width, | ||
uint32_t value) | ||
{ | ||
if (!aclint_sswi_reg_write(sswi, addr, value << (RV_MEM_SW - width))) | ||
vm_set_exception(hart, RV_EXC_STORE_FAULT, hart->exc_val); | ||
} |
This file was deleted.
Oops, something went wrong.
Oops, something went wrong.
Oops, something went wrong.
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I'm uncertain if the CLINT-related implementation will still exist once ACLINT is fully implemented. If it does, add an option here to use CLINT when ACLINT is unavailable.