If it is not specified, the issues listed below affect all MR6 samples. See the potential fixes in sub-minirun6 by the end of this page.
-
larnd-sim
-
Field response
- MiniRun6 uses the new field responses (v2a, v2b) without update the time configuration. Charge of the hits are incomplete.
- PicoRun6.1a, same as MiniRun6, uses the new field responses but not the extended time configuration and the data-like threshold and LArPix voltage.
- PicoRun6.1b, listed for completeness, used the old field responses and the data-like threshold and LArPix voltage.
- PicoRun6.1c, uses the new field response and the extended time configuration (time_padding & time_window = 191us), as well as the data-like threshold and LArPix voltage.
-
More packets have > 1 summed fraction compared to MR6
-
-
ndlar_flow
- Light channel mapping is incorrect. (Fix in PR#139, not applied in MiniRun6, unclear for PicoRun6.1).
- No light hits in the second TPC (ADC channel ID > 32)
- Charge-light matching reference is broken
- Flash to light event reference is broken
-
tpc
variable inlight/flash/data
is almost always even. When odd, it is always 1.
-
Reconstruction -- SPINE
- The training sample (mpvmpr) uses old responses
-
Reconstruction -- Pandora
-
Mx2
-
CAF
- Missing pandora merged CAFs