# Replication of Parasuraman, Molloy and Singh (1993)
# This experiment aims to investigate the performance consequences of automation-induced complacency
# Example of a low-reliability block (10 minutes, with 56.25% or 9 of 16 malfunctions detected)
# Timestamp in h:mm:ss format. Duration values in milliseconds.
# 1. Set tasks parameters
# 1.a. System monitoring parameters
0:00:00;sysmon;scales-1-name;TEMP1
0:00:00;sysmon;scales-2-name;PRES1
0:00:00;sysmon;scales-3-name;TEMP2
0:00:00;sysmon;scales-4-name;PRES2
0:00:00;sysmon;lights-1-name;OK
0:00:00;sysmon;lights-2-name;WARNING
0:00:00;sysmon;automaticsolverdelay;4000
0:00:00;sysmon;feedbackduration;1500
0:00:00;sysmon;alerttimeout;10000
# 1.b.i. Resources management parameters
# Empty (default parameters used)
# 1.b.ii. Pumps status parameters
# Empty (default parameters used)
# 1.c. Tracking parameters
0:00:00;track;cursorcolor;#009900
0:00:00;track;cutofffrequency;0.06
0:00:00;track;equalproportions;False
# 2. Start appropriate tasks
0:00:00;pumpstatus;start
0:00:00;resman;start
0:00:00;track;start
0:00:00;sysmon;start
# 3. Set scenario events
# 3.a. System monitoring events (16 system malfunctions : example of a low-reliability block [56.25% of automatic resolving])
# Warning light onset during automatic solving is managed explicitly
0:00:34;sysmon;scales-1-failure;down
0:00:34;sysmon;automaticsolver;True
0:00:34;sysmon;lights-2-on;True
0:00:59;sysmon;scales-3-failure;up
0:00:59;sysmon;automaticsolver;True
0:00:59;sysmon;lights-2-on;True
0:01:42;sysmon;scales-2-failure;down
0:01:42;sysmon;automaticsolver;False
0:01:42;sysmon;lights-2-on;False
0:02:03;sysmon;scales-1-failure;up
0:02:03;sysmon;automaticsolver;True
0:02:03;sysmon;lights-2-on;True
0:02:58;sysmon;scales-4-failure;down
0:02:58;sysmon;automaticsolver;False
0:02:59;sysmon;lights-2-on;False
0:03:26;sysmon;scales-2-failure;down
0:03:26;sysmon;automaticsolver;False
0:03:26;sysmon;lights-2-on;False
0:04:04;sysmon;scales-1-failure;up
0:04:04;sysmon;automaticsolver;True
0:04:04;sysmon;lights-2-on;True
0:04:28;sysmon;lights-2-failure;True
0:04:28;sysmon;automaticsolver;False
0:04:28;sysmon;lights-2-on;True
0:05:38;sysmon;scales-4-failure;down
0:05:38;sysmon;automaticsolver;False
0:05:38;sysmon;lights-2-on;False
0:06:12;sysmon;scales-2-failure;up
0:06:12;sysmon;automaticsolver;False
0:06:12;sysmon;lights-2-on;False
0:06:30;sysmon;lights-2-failure;True
0:06:30;sysmon;automaticsolver;True
0:06:30;sysmon;lights-2-on;True
0:07:14;sysmon;scales-1-failure;down
0:07:14;sysmon;automaticsolver;True
0:07:14;sysmon;lights-2-on;True
0:07:55;sysmon;scales-3-failure;up
0:07:55;sysmon;automaticsolver;True
0:07:55;sysmon;lights-2-on;True
0:08:17;sysmon;scales-1-failure;down
0:08:17;sysmon;automaticsolver;False
0:08:17;sysmon;lights-2-on;False
0:08:55;sysmon;lights-1-failure;True
0:08:55;sysmon;automaticsolver;False
0:08:55;sysmon;lights-2-on;False
0:09:31;sysmon;scales-4-failure;down
0:09:31;sysmon;automaticsolver;True
0:09:31;sysmon;lights-2-on;True
# 3.b. Resources management events
# Empty
# 3.c. Tracking events
# Empty
# 4. End tasks at 10 minutes
0:10:00;pumpstatus;stop
0:10:00;resman;stop
0:10:00;track;stop
0:10:00;sysmon;stop
0:10:01;end